ABB Magne 3 Product Manual page 36

Electromagnetic process lock
Table of Contents

Advertisement

Magne 4 DYN:
DYN output
Response time at activation
Response time at
deactivation
Magne 4 OSSD:
OSSD output
Response time at activation
Response time at
deactivation
Voltage drop for OSSD
output
Power from switched off
position (OSSD out)
Safety / Harmonized standards
Conformity
Application standard
compliance
Functional safety standard
compliance
Warning!
Electrical safety standard
compliance
Electromagnetic
compatibility standard
compliance
Certificates
Information for use in USA/Canada (UL)
Enclosure
Intended usage
Connecting cables
2TLC172315M0201 Rev.M3
15 mA (current limited)
<100 ms
<30 ms
Max. 50 mA per output (current limited)
<100 ms
First unit <30 ms
For each additional unit < 10 ms
VCC - 2.5 VDC at 25 mA
<3 µA
European Machinery Directive 2006/42/EC
EMC directive 2014/30/EU
RoHS directive 2011/65/EU
RoHS3 directive 2015/863
EN ISO 14119:2013
EN ISO 12100:2010
EN ISO 13849-1:2015, PL e/Category 4, PFH
EN ISO 13849-2:2012
EN 62061:2005+A1:2012+A2:2015, SIL3, PFH
EN 61508:2010, SIL3, PFH
The safety related values are based on interlocking
device Eden and are not valid for the locking function.
EN 60204-1:2006+A1:2009
EN 60664-1:2007
EN 60947-5-2:2007+A1:2012
EN 60947-5-3:2013
cULus, TÜV Süd
Type 1
Applications according to NFPA 79
Cables to comply with CYJV/7, with a conductor area of
2
min. 0.2 mm
.
= 4.50·10
D
= 4.50·10
D
-9
= 4.50·10
D
-9
-9
36