Functions

7.1

Locking function

Power is needed to lock Magne. A loss of power will result in unlocking.
Locking:
• Close the door.
• Lock by applying +24 VDC on the locking pin.
Unlocking:
• Unlock by removing +24 VDC from the locking pin.
• Open the door.
7.2

Interlocking function

An interlocking function monitors the door position, open or closed, but it does not prevent
the door from being opened.
7.3

LED Indications

Status LED indications show the status of Magne and its outputs.
Magne 3 and Magne 4 have one blue LED (locked/unlocked indicator).
Magne 4 also has one green and one red LED (Eva position indicator).
Model
Magne 3 +
Magne 4
Magne 3 +
Magne 4
Magne 4
Magne 4
Magne 4
Magne 4
Magne 4
Magne 4
Magne 4
(OSSD)
See recommended actions to take in chapter 'Troubleshooting'.
2TLC172315M0201 Rev.M3
LED Indication
Description
Blue
Magne is locked
Blue flashing
Lock signal, but Magne is not detecting the
anchor plate
Green
Eva within sensing distance of Adam (door
closed)
Green flashing
Eva within 2 mm from maximum sensing
distance (door closed)
Green-Red
Eva within sensing distance, safety circuit
flashing
before this unit broken (door closed)
Red
Eva out of sensing distance (door open)
Red flashing
Eva code not stored in Adam
Red fast
Fail safe mode
flashing
Red-Red-Green
Invalid input signal
fast flashing
Safety
circuit
N/A
N/A
Closed
Closed
Open
Open
Open
Open
Open