9

Troubleshooting

9.1

LED indications

Magne 3 and Magne 4 LED Indications:
LED indication
No LED light
Blue flashing
Magne 4 LED indications:
LED indication
Green flashing
Red solid light
Green and Red at
the same time
Green-Red fast
flashing
Red fast flashing
Green-Red flashing
Red-Red-Green fast
flashing (OSSD only)
9.2

Sensing distance Eva and Adam

To improve the sensing performance between Eva and Adam, minimize the gap (Z distance)
by installing distance plate (DA 1B) between the Eva unit and the bracket holding Eva. See
chapter "Positioning and orientation of Eva with Magne 4" for more details.
2TLC172315M0201 Rev.M3
Probable cause
No voltage
Anchor plate is missing
or not centered
Probable cause
Eva within 2 mm from
maximum sensing
distance
Eva out of sensing
distance, safety circuit
broken (door open)
Metal between Adam
and Eva
Unit is defective
Valid Eva code missing
Fail safe mode
Input signal is missing
Invalid input signal
Action
Check +24 VDC power supply.
Check anchor plate position.
Action
Adjust Eva position.
Move Eva within sensing distance of
Adam (close door).
Remove metal.
Replace the unit.
Perform procedure to replace Eva. If
fault indication remains, the unit is
defective and must be replaced.
Power cycle (i.e. turn off power, wait for
one minute and turn it on again).
1. Check output signal from the
previous unit in the signal chain.
2. Turn off power supply.
3. Move Eva within sensing distance of
Adam.
4. Power supply.
Power cycle (i.e. turn off power, wait for
one minute and turn it on again). If
fault indication remains, check
incoming signals.
2 8