Asus GigaX 2008EX User Manual page 52

Layer 2 managed switch
Table of Contents

Advertisement

GigaX2008EX L2 Managed Switch User Manual
CLI command: l2 vlan remove <vlan id> <port list>
CLI command: l2 vlan utportadd <vlan id> <untagged port list>
[Remove VLAN]
Allows user to completely destroy an existing VLAN.
CLI command: l2 vlan delete <vlan id>
[Reload]
Restores the previous saved settings from configuration file.
CLI command: l2 vlan retrieve
[Show Port]
Displays the port configuration
CLI command: l2 port show <port id or * for all ports>
[PVID]
Sets the default VLAN for a port by giving a VLAN ID and its associated port
member list.
CLI command: l2 port vlan <vlan id, 4095 to disable the port-based vlan>
<port list>
[CoS Value]
Sets the Class of Service for a port by assigning it a priority (with range of 0-7)
criteria value for untagged packets..
CLI command: l2 port priority <CoS> <port list>
[Reload]
Restores the previous saved settings from configuration file.
CLI command: l2 port retrieve
[CoS] [Map]
Allows user to map the CoS priority (with range of 0-7) for a buffer queue (total
of 4, with queue ID of 1-4).
CLI command: l2 cos map <queue id (1-4)> <cos (0-7)>
[Scheduling Algorithm] [Strict/WRR]
Allows user to set scheduling with strict priority based or weight priority based.
CLI command: l2 cos sched <mode (1: strict 2: weighted round robin)>
42

Advertisement

Table of Contents

Troubleshooting

loading

Table of Contents