Dell EU2SPE Disassembly Instructions Manual page 13

Advertisement

Remove a fan
Remove the air duct
This procedure describes how to remove a fan.
Before you begin
The SP must be removed from the chassis to remove the fans.
Procedure
1. Identify the failed fan. The SP fault LED, located at the bottom left rear of the
chassis, will show an amber color if there is a fan failure.
2. Press the locking tabs inward to release the fan from its mounting location.
Firmly pull the fan straight up and remove it from the SP.
Remove the air duct before removing or replacing the DIMMs . This procedure
describes how to remove the air duct.
Before you begin
The storage processor must be removed from the chassis before the air duct can be
removed.
Procedure
1. Grasp the air duct firmly.
2. Firmly pull the air duct up to remove it from the storage processor.
WEEE Disassembly Instructions
Disassembly instructions
13