Setting, Unsetting, and Restoring the System
5.2

Setting the System: PARTSET A

5.3

Setting the System: PARTSET B

5.4

Failing to Set the System

12
Siemens Building Technologies
Fire Safety & Security Products
The PARTSET A option provides the following functionality:
Perimeter protection to a building while
allowing free movement through the exit and
access areas.
Exclusion of EXCLUDE A zones from
protection
Instant activation of alarm on selection of
mode; by default there are no exit times
associated with PARTSET A
To select PARTSET A, enter a valid user code, scroll to the PARTSET A option
and press SELECT (right soft key).
If the alarm fails to set, see Section 5.4.
The PARTSET B option provides the following functionality:
Perimeter protection to a building while
allowing free movement through the exit and
access areas.
Exclusion of EXCLUDE B zones from
protection
Instant activation of alarm on selection of
mode; by default there are no exit times
associated with PARTSET B
To select PARTSET B, enter a valid user code, scroll to the PARTSET B option
and press SELECT (right soft key).
If the alarm fails to set, see section 5.4.
NOTE
Partset A and Partset B configuration modes are dependent upon the system has been programmed.
The system fails to set if there is an open or fault condition detected on an alarm
zone when the FULLSET or PARTSET A/B option is selected. The Keypad
displays the zone number and description.
To set the system, locate the zone and close or fix the fault. Repeat the FULLSET
or PARTSET A/B operation.
...PARTSET A?...
EXIT
SELECT
18/06/2008
12:30
PARTSET A SET
...PARTSET B?...
EXIT
SELECT
18/06/2008
12:30
PARTSET B SET