Sensor Technical Data - Siemens SITRANS DA400 Operating Instructions Manual

Process monitoring
Table of Contents

Advertisement

Technical data

9.2 Sensor technical data

9.2
Sensor technical data
Rated conditions
Permissible operating temperature
Degree of protection according to EN 60529
Mechanical load
Climate class
Construction
Housing material
Cable
Weight
Dimensions (W x H x D) in mm (inches)
Certificates and approvals
Protection against explosion
Intrinsic safety "i"
Identification
Permissible ambient temperature
82
Piezoceramic sensor with pre-amplifier
Encapsulated electronics
4-wire cable with anti-kink sleeve
Use as category 1 G device
Use as category 2 G device
Use as category 1 D device or as
category 2 D device
-40 °C ... 110 °C ( -40 °F ... 230 °F)
IP66/IP68
Class 4M7 to DIN EN 60721-3-4
Class 4K4 to DIN EN 60721-3-4
Stainless steel 1.4571 (316Ti SST)
Ends with connector sleeves and cable lug
for connection to SITRANS DA400
125 g (0.276 lb)
26 x 29 x 40 (1.02 x 1.14 x 1.57)
TÜV 05 ATEX 2876 X
Ex II 1 G EEx ia IIC T6/T5/T4 or
Ex II 1 D Ex iaD 20, 21, 22 T160
Temperature class
T6
T5
T4
T6
T5
T4
T160
SITRANS DA400 for material flow monitoring with protection against explosion
Temperature range
-20 °C to +50 °C
-20 °C to +60 °C
-20 °C to +60 °C
-40 °C to +65 °C
-40 °C to +80 °C
-40 °C to +110 °C
-40 °C to +110 °C
Operating Instructions, 09/2007, A5E00841152-01