Connecting Jig(S); The Location Of Jig Terminals; Layout Of Jig Terminals - Panasonic YD-500GP5 Operating Instructions Manual

Digital igbt control mig/mag power source
Table of Contents

Advertisement

6.5 Connecting jig(s)

The location of
6.5.1
There are two types of jig terminals (Jig terminals 1 and 2)
(1) Jig terminal 1
To send out a command for the emergency stop and
temporary stopping from a jig or another device.
To send out the current detection signal to a jig or another
device.
Location: On the chassis inside the product.
(2) Jig terminal 2
To install an external voltmeter or ammeter.
Location: On the chassis inside the product.
Note:
● Keep the communication cables away from the
welding arc area, the welding torch, the base-
material-side cable, etc. to prevent troubles
caused by incorporation of the high frequency
wave. And keep the wiring length within 10m.
Lead wires from the wiring port. (Make a cut in
the grommet wall to insert wires.)

Layout of jig terminals

6.5.2
* Connect the start signal of this product to the torch switch receptacle of the wire feeder.
When touching a printed circuit board, observe the following item to prevent
electrostatic destruction of the printed circuit board.
Before starting an operation, for example, touch any metal part of the case
with your hand to discharge static electricity.
jig terminals
Connection
External
terminal block 1
30
External
terminal block 2

Hide quick links:

Advertisement