2 Installation
2.3 Connecting the cables
Continued
1
2
3
4
5
6
7
8
9
10
11
30
Action
Connect the wires to the emergency stop
button and tighten the holding screws.
CAUTION
The color code of the wires in the retractable
cable do not match the color coding of the
original. See the preceding table and figure.
Connect GN-11 and YE-12 on the first
emergency channel.
Connect WH-21 and BN-22 on the
second emergency channel.
Tighten the sealing ring of the emergency
stop button.
Connect the main connector.
Put the grounding clamp in position and
tighten the screw.
Put the retractable cable in position and at-
tach the clamps and screws.
Adjust the length of the cable and put the
gasket into the slot.
Safety the cable and wires with plastic straps.
Connect the connector of the teach pendant
back cover.
Put the housing cover in place. Make sure
that no wires are squeezed.
Tighten the screws.
CAUTION
Verify that the emergency stop button and
the three-position enabling device are work-
ing.
© Copyright 2015-2016 ABB. All rights reserved.
Note
xx1300002542
See position D in the figure.
See position C in the figure.
See position A in the figure.
See position B in the figure.
See position E in the figure.
This step is mandatory.
Product manual - FlexPendant Retractable Cable