ABB FlexPendant Product Manual page 34

Table of Contents

Advertisement

3 Maintenance
3.2 Inspecting the complete FlexPendant Retractable Cable
Continued
3
4
5
6
7
8
9
10
34
Action
Examine the integrity of all the external plastic
elements.
Examine the cable jacket and make sure that the
cable is not twisted. Use the black line print on
the cable to detect torsion.
Examine that the cable stopper is in place and
cannot be moved.
Examine that no foreign objects or liquids are in-
side the cable reel. If so, remove it.
To test the stop device, retraction spring, and
brake:
1 Pull out at least 2 meters of the retractable
cable to make sure that the stop device is
working, that is, that the cable stays pulled
out. There should be a click-clack sound
while pulling out the cable.
2 Pull out the entire retractable cable and
release it so the cable retracts. Examine
that the entire cable length is retracted
slowly.
3 Pull out cable and release it. Stop the re-
traction to make sure that the stop device
is working.
4 Repeat 4 times.
Examine that there is sealing glue on all locking
screws. Do not remove the glue.
Examine the cleaning roller.
Examine the handle.
© Copyright 2015-2016 ABB. All rights reserved.
Note
If the brake too fast, then it should
be replaced, see
brake on page
xx1600000640
Product manual - FlexPendant Retractable Cable
3HAC048816-001 Revision: B
Replacing the
37.