DOK-SUPPL*-VSB*40.1***-PR03-EN-P
Rexroth IndraControl VSB 40.1 Control Cabinet PC
7.2.12

PC Voltage Supply

DC-24-V voltage supply
NOTICE
Only connect devices with the same display interface.
This screw connection is used for device variants for DC 24 V. All internally
required voltages are generated from the DC 24 V supply.
Fig.7-17:
Connection terminals for DC 24 V supply
NOTICE
Use only copper wire for wiring the connection terminals. Tighten the screws of
the screw terminals with a torque of 4 lb in (0.4 Nm).
Parameter
Input voltage U
N
Residual ripple at U
N
Current consumption at DC 19 V
Overload protection
Short-circuit protection
Fig.7-18:
DC 24 V connection, technical data
DANGER
The DC 24 V input voltage must comply with the requirements of the
"Protective separation"!
Plug and unplug the connector only if there is no voltage!
Bosch Rexroth AG
Malfunction or no function due to devices with
different display interface.
Destruction of screw terminals, insufficient
contact and loss of UL certification if no copper
wire is used.
Value
DC 24 V; (DC 19 V...DC 32 V)
See figure on the following page
20 A max.
Deactivation with automatic restart
Deactivation with automatic restart
Danger without protective separation!