Installation (For Installers); Precautions For Installation - Panasonic KY-C223B Operating & Installation Instructions Manual

Induction heating cooktop
Table of Contents

Advertisement

Installation
(for installers)

Precautions for Installation

To avoid risks of electric shock, fire, smoke, burns, scalds, injury or property loss
Failure to follow these advice may result in electrical shock or death.
Disconnect the appliance from the power supply before carrying out any work or maintenance.
Connection to a good earth wiring system is essential and mandatory.
Alterations to the domestic wiring system must only be made by a qualified electrician.
Please pay attention to sharp edges.
It may result in injury or cuts.
Read these instructions carefully before installing or using this appliance.
No combustible materials or products should be placed on this appliance at any time.
In order to avoid a hazard, this appliance must be installed according to these instructions.
This appliance must be properly installed and earthed only by a qualified person.
This appliance should be connected to a circuit which incorporates an isolation switch providing
full disconnection from the power supply.
Failure to install the appliance correctly could invalidate any warranty or liability claims.
The countertop is square, leveled, and no structural members interfere with space requirements.
The countertop is made of a heat-resistant material.
If the appliance is installed above an oven, the oven should have a built-in cooling fan.
The installation must comply with all clearance requirements and applicable standards and
regulations.
A suitable isolation switch providing full disconnection from the main power supply is incorporated
in the permanent wiring, mounted and positioned to comply with the local wiring rules and
regulations. The isolation switch must be of an approved type The isolation switch must be an
approved type, and all the electrodes (or all valid [phase] conductors, if the local wiring rules allow
this change to the requirements) have an air gap contact distance of 3 mm.
The isolation switch should be easily accessible to the customer.
If you have any question about installation, please consult the local building authorities to review
the rules.
You should use heat-resistant and easy-to-clean finishes (such as ceramic tiles) for the wall
surfaces surrounding the appliance.
EN20
CAUTIONS
Before installing the appliance, make sure that