Download Print this page
Huawei XH628 V5 Quick Start Manual

Huawei XH628 V5 Quick Start Manual

Server node

Advertisement

Quick Links

XH628 V5 Server Node Quick Start Guide
Document issue: 03 (2018-12-04)
BOM: 31509966(4/4)
1 Overview
The XH628 V5 is a 2-socket dual-slot balanced storage server node on the Huawei
X6800 server.
The XH628 V5 supports a maximum of twelve 3.5-inch or 2.5-inch high-speed hard
disks using a hard disk drawer, 16 DDR4 DIMMs, and four standard PCIe cards.
The XH628 V5 provides powerful computing performance, large internal storage
capacity, and good expansion of external ports, ideal for various application scenarios
such as data centers, cloud computing, big data, and Internet.
The following figure shows the appearance of the XH628 V5.
The following table lists the technical specifications for the XH628 V5. For details, see
the XH628 V5 Server Node V100R005 User Guide.
Category
Item
Specifications
Mechanical
Dimensions
166 mm x 108 mm x 745 mm (6.54 in. x 4.25 in. x
specifications
(H x W x D)
29.33 in.)
Color
Front panel: black
Shell: silver
Weight
Net weight: 21.5 kg (47.4 lb)
Temperature
Environmental
Operating temperature: 5° C to 40° C (41° F to
specifications
104° F)
Storage temperature: –40° C to +65° C (–40º F to
+149º F)
Long-term storage temperature: 21℃ to 27℃
(69.8℉ to 80.6℉)
NOTE
The maximum temperature of the supercapacitor is
33°C (CPU power = 165 W), 35°C (150W ≤
CPU power < 165 W), and 40°C (CPU power < 150
W).
The maximum operating temperature of the server is
35° C (95° F) if 6144, 6146, 8176, 8170, or 6150
CPUs are used.
If one fan fails, the maximum operating temperature
of the server is 5° C (9° F) lower than that in normal
cases.
1
Category
Item
Specifications
The XH628 V5 supports mixed configuration with
only the XH628 V3 nodes in one chassis. In this case,
the supported operating environment temperature is
the same as that of the XH628 V5.
Humidity
Operating humidity: 10% RH to 85% RH
(non-condensing)
Storage humidity: 5% RH to 95% RH
(non-condensing)
Long-term storage humidity: 30% RH to 69% RH
(non-condensing)
Altitude
Operating altitude: ≤ 3000 m (9842.4 ft)
Storage altitude: ≤ 12,000 m (39369.6 ft)
When the X6800 is used at an altitude of higher
than 900 m (2952.72 ft), the operating
temperature decreases by 1° C (1.8° F) as the
altitude increases by 300 m (984.24 ft).
At an altitude of over 3000 m (9842.4 ft), only
Titanium PSUs can be used.
HDDs are not supported at an altitude of over
3000 m (9842.4 ft).
Power supply
Rated input
12 V DC
specifications
voltage
2 Front Panel
The XH628 V5 supports two types of front panels:
Front panel with two front 2.5-inch hard disks (see the figure on the left)
Front panel with two half-height full-length standard PCIe cards (see the figure on
the right)
No.
Component
No.
Component
1
Universal connector port (UCP)
2a
Front hard disk (HDD20)
Ejector lever
Front standard PCIe card (PCIe
2b
3
1)
4
LOM port 1 (10GE optical port)
5
LOM port 2 (10GE optical port)
6
Ejector release button
7
Power button/indicator
8
9
Health status indicator
UID button/indicator
Service network port activity
LOM port 3 (GE electrical port)
10
11
indicator
2
No.
Component
No.
Component
Service network port link indicator
Front hard disk (HDD21)
12
13a
LOM port 4 (GE electrical port)
Front standard PCIe card (PCIe
13b
14
2)
15
iBMC management network port
16
Hard disk activity indicator
17
Hard disk fault indicator
18
Hard disk drawer
19
Hard disk enclosure latch
20
Handle
Hard disk enclosure fault indicator
Hard disk enclosure activity
21
22
indicator
The XH628 V5 supports two GE and two 10GE LOM NICs.
3 Obtaining Tools
ESD wrist strap or ESD gloves: used to prevent ESD damage.
4 Installing the XH628 V5
1.
Before operating the XH628 V5, wear ESD clothes and gloves, and remove
conductive objects such as jewelry and watches.
2.
Before installing the XH628 V5, ensure that the required optional components,
such as the RAID controller card, have been installed. For details about the
installation procedures, see the XH628 V5 Server Node V100R005 Installation
Guide.
3.
Push the spring on the filler panel in the arrow direction, and remove the filler panel
from the chassis by holding the ejected part of the filler panel. See steps (1) and (2)
in the following figure on the left.
4.
Press the latch on the XH628 V5, and raise the ejector lever. See steps (1) and
(2) in the preceding figure on the right.
5.
Insert the XH628 V5 into the chassis horizontally and lower the ejector lever. See
steps (3) in the preceding figure on the right.
CAUTION
If the XH628 V5 cannot be properly installed, do not insert it forcibly into the chassis.
Otherwise, the XH628 V5 may be damaged. Pull out the XH628 V5 carefully, and
install it by following the instructions.
When removing the XH628 V5, hold its bottom with both hands to avoid personal injury
or device damage.
5 Powering On the XH628 V5
The power-on of the XH628 V5 varies according to different scenarios.
The chassis is not powered on.
Power on the chassis. Then the XH628 V5 is powered on along with the chassis.
The chassis is powered on, and the XH628 V5 is not installed in the chassis.
After the XH628 V5 is installed, it powers on automatically. For details about how to
install the XH628 V5, see
chapter
4.
The chassis is powered on, and the XH628 V5 is installed but is faulty.
3

Advertisement

loading

Summary of Contents for Huawei XH628 V5

  • Page 1 (H x W x D) 29.33 in.) ● Color Press the latch on the XH628 V5, and raise the ejector lever. See steps (1) and Front panel: black (2) in the preceding figure on the right. ● Shell: silver Insert the XH628 V5 into the chassis horizontally and lower the ejector lever.
  • Page 2 Hold down the power button on the front panel for 6 seconds until the XH628 V5 is powered off, and then press the power button again to power on the XH628 V5. If the power restore policy is set to Stay Off for the server, manually power on the server after the power supply is connected.