Mitsubishi Electric A800 Instruction Manual page 57

Hide thumbs Also See for A800:
Table of Contents

Advertisement

Parameter list
Pr.
Name
First free thermal
0 to 590Hz,
602
reduction frequency 2
9999
First free thermal reduction
603
1 to 100%
ratio 2
First free thermal
0 to 590Hz,
604
reduction frequency 3
9999
Power failure stop
606
external signal input
0, 1
selection
Motor permissible load
607
110 to 250%
level
Second motor
110 to 250%,
608
permissible load level
9999
PID set point/deviation
609
1 to 5
input selection
PID measured value
610
1 to 5
input selection
Acceleration time at a
0 to 3600s,
611
restart
9999
Cumulative pulse clear
635
0 to 3

signal selection
Cumulative pulse
636
1 to 16384

division scaling factor
Control terminal option-
637
Cumulative pulse
1 to 16384

division scaling factor
Cumulative pulse
638
0 to 3

storage
Brake opening current
639
0, 1
selection
Brake operation
640
0, 1
frequency selection
Second brake
641
sequence operation
0, 7, 8, 9999
selection
Second brake opening
642
0 to 30Hz
frequency
Second brake opening
643
0 to 400%
current
Second brake opening
644
0 to 2s
current detection time
Second brake operation
645
0 to 5s
time at start
Second brake operation
646
0 to 30Hz
frequency
Second brake operation
647
0 to 5s
time at stop
Second deceleration
648
detection function
0, 1
selection
Second brake opening
650
0, 1
current selection
Second brake operation
651
0, 1
frequency selection
Speed smoothing
653
0 to 200%
control
Speed smoothing cutoff
654
0 to 120Hz
frequency
Analog remote output
655
0, 1, 10, 11
selection
656
Analog remote output 1
657
Analog remote output 2
800 to 1200%
658
Analog remote output 3
659
Analog remote output 4
Increased magnetic
660
excitation deceleration
0, 1
operation selection
Magnetic excitation
661
0 to 40%, 9999 9999
increase rate
Increased magnetic
662
0 to 300%
excitation current level
Control circuit
663
temperature signal
0 to 100°C
output level
Regeneration avoidance
665
0 to 200%
frequency gain
Power failure stop
668
0 to 200%
frequency gain
SF-PR slip amount
673
adjustment operation
2, 4, 6, 9999
selection
SF-PR slip amount
674
0 to 500%
adjustment gain
679
Second droop gain
0 to 100%, 9999 9999
Second droop filter time
680
0 to 1s, 9999
constant
Second droop function
0, 1, 2, 10, 11,
681
activation selection
9999
Second droop break
0.1 to 100%,
682
point gain
9999
Second droop break
0.1 to 100%,
683
point torque
9999
Tuning data unit
684
0, 1
switchover
686
Maintenance timer 2
0(1 to 9998)
Maintenance timer 2
687
0 to 9998, 9999 9999
warning output set time
20
DRIVE THE MOTOR
Setting
Initial
Pr.
range
value
688
Maintenance timer 3
9999
Maintenance timer 3
689
warning output set time 0 to 9998, 9999 9999
100%
Deceleration check time 0 to 3600s,
690
9999
Second free thermal
692
reduction frequency 1
1
Second free thermal
693
reduction ratio 1
Second free thermal
150%
694
reduction frequency 2
Second free thermal
9999
695
reduction ratio 2
2
Second free thermal
696
reduction frequency 3
699
Input terminal filter
3
Maximum motor
702
frequency
9999
Induced voltage
706
0
constant (phi f)
707
Motor inertia (integer)
1
711
Motor Ld decay ratio
712
Motor Lq decay ratio
1
Starting resistance
717
tuning compensation
Starting magnetic pole
0
721
position detection pulse
width
0
724
Motor inertia (exponent) 0 to 7, 9999
Motor protection current
0
725
level
Second motor induced
738
0
voltage constant (phi f)
Second motor Ld decay
739
ratio
3Hz
Second motor Lq decay
740
ratio
130%
Second starting
741
resistance tuning
0.3s
compensation
0.3s
Second motor magnetic
742
pole detection pulse width
6Hz
Second motor
743
maximum frequency
0.3s
Second motor inertia
744
(integer)
0
Second motor inertia
745
(exponent)
Second motor
0
746
protection current level
Second motor low-
0
747
speed range torque
characteristic selection
0
20Hz
Second PID action
753
0
selection
1000%
1000%
1000%
Second PID control
1000%
754
automatic switchover
frequency
0
Second PID action set
755
point
Second PID
756
proportional band
Second PID integral
100%
757
time
Second PID differential
758
0°C
time
759
PID unit selection
100%
Pre-charge fault
760
selection
100%
761
Pre-charge ending level 0 to 100%, 9999 9999
762
Pre-charge ending time
9999
Pre-charge upper
763
detection level
100%
764
Pre-charge time limit
Second pre-charge
765
9999
fault selection
Second pre-charge
766
9999
ending level
Second pre-charge
767
9999
ending time
Second pre-charge
768
9999
upper detection level
Second pre-charge
769
0
time limit
0
Setting
Initial
Name
range
value
0(1 to 9998)
0
1s
9999
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
1 to 100%
100%
0 to 590Hz,
9999
9999
5 to 50ms, 9999 9999
0 to 400Hz,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
10 to 999, 9999 9999
0 to 100%, 9999 9999
0 to 100%, 9999 9999
0 to 200%, 9999 9999
0 to 6000μs,
10000 to
9999
16000μs, 9999
9999
100 to 500%,
9999
9999
0 to 5000mV/
9999
(rad/s), 9999
0 to 100%, 9999 9999
0 to 100%, 9999 9999
0 to 200%, 9999 9999
0 to 6000μs,
10000 to
9999
16000μs, 9999
0 to 400Hz,
9999
9999
10 to 999, 9999 9999
0 to 7, 9999
9999
100 to 500%, 9999 9999
0, 9999
9999
0, 10, 11, 20, 21,
50, 51, 60, 61,
70, 71, 80, 81,
90, 91, 100,
101, 1000,
0
1001, 1010,
1011, 2000,
2001, 2010,
2011
0 to 590Hz,
9999
9999
0 to 100%, 9999 9999
0.1 to 1000%,
100%
9999
0.1 to 3600s,
1s
9999
0.01 to 10.00s,
9999
9999
0 to 43, 9999
9999
0, 1
0
0 to 3600s,
9999
9999
0 to 100%, 9999 9999
0 to 3600s,
9999
9999
0, 1
0
0 to 100%, 9999 9999
0 to 3600s,
9999
9999
0 to 100%, 9999 9999
0 to 3600s, 9999
9999
Setting
Pr.
Name
range
Operation panel
1 to 3, 5 to 14,
774
monitor selection 1
17 to 20, 22 to 36,
38, 40 to 46,
Operation panel
775
50 to 57, 61, 62,
monitor selection 2
64, 67, 71 to 74,
Operation panel
87 to 98, 100,
776
monitor selection 3
9999
4 mA input check
777
0 to 590Hz, 9999
operation frequency
778
4 mA input check filter
0 to 10s
Operation frequency
779
during communication
0 to 590Hz, 9999
error
Low speed range
788
torque characteristic
0, 9999
selection
Acceleration time in
791
0 to 3600s, 9999
low-speed range
Deceleration time in
792
0 to 3600s, 9999
low-speed range
Pulse increment setting
0.1, 1, 10,
799
for output power
100, 1000kWh
0 to 6, 9 to 14,
Control method
800
20, 100 to 106,
selection
109 to 114
802
Pre-excitation selection 0, 1
Constant output range
803
torque characteristic
0, 1, 10, 11
selection
Torque command
804
0, 1, 3 to 6
source selection
Torque command value
805
600 to 1400%
(RAM)
Torque command value
806
600 to 1400%
(RAM,EEPROM)
807
Speed limit selection
0 to 2
Forward rotation speed
808
0 to 400Hz
limit/speed limit
Reverse rotation speed
809
limit/reverse-side speed
0 to 400Hz, 9999
limit
Torque limit input method
810
0 to 2
selection
811
Set resolution switchover 0, 1, 10, 11
Torque limit level
812
0 to 400%, 9999
(regeneration)
Torque limit level (3rd
813
quadrant)
Torque limit level (4th
814
quadrant)
815
Torque limit level 2
0 to 400%, 9999
Torque limit level during
816
acceleration
Torque limit level during
817
deceleration
Easy gain tuning
818
1 to 15
response level setting
819
Easy gain tuning selection 0 to 2
820
Speed control P gain 1 0 to 1000%
Speed control integral
821
0 to 20s
time 1
822
Speed setting filter 1
0 to 5s, 9999
823
Speed detection filter 1 0 to 0.1s

Torque control P gain 1
824
(current loop
0 to 500%
proportional gain)
Torque control integral
825
time 1 (current loop
0 to 500ms
integral time)
826
Torque setting filter 1
0 to 5s, 9999
827
Torque detection filter 1 0 to 0.1s
828
Model speed control gain 0 to 1000%
830
Speed control P gain 2 0 to 1000%, 9999 9999
Speed control integral
831
0 to 20s, 9999
time 2
832
Speed setting filter 2
0 to 5s, 9999
833
Speed detection filter 2 0 to 0.1s, 9999

834
Torque control P gain 2 0 to 500%, 9999
Torque control integral
835
0 to 500ms, 9999 9999
time 2
836
Torque setting filter 2
0 to 5s, 9999
837
Torque detection filter 2 0 to 0.1s, 9999
0 to 3, 24, 25,
840
Torque bias selection
9999
600 to 1400%,
841
Torque bias 1
9999
600 to 1400%,
842
Torque bias 2
9999
600 to 1400%,
843
Torque bias 3
9999
844
Torque bias filter
0 to 5s, 9999
845
Torque bias operation time 0 to 5s, 9999
Torque bias balance
846
0 to 10V, 9999
compensation
Fall-time torque bias
847
0 to 400%, 9999
terminal 1 bias
Initial
value
9999
9999
9999
9999
0s
9999
9999
9999
9999
1kWh
20
0
0
0
1000%
1000%
0
60/50Hz

9999
0
0
9999
9999
9999
9999
9999
9999
2
0
60%
0.333s
9999
0.001s
100%
5ms
9999
0s
60%
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999
9999