0000003417.BOOK 71 ページ 2014年10月22日 水曜日 午前10時35分
Power supply for indoor and outdoor units (CONTINUED)
1. Electrical work
1-2-2. Electrical characteristics of Outdoor unit at cooling mode
PURY-P-YLM
PURY-P200YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P400YSLM-A(-BS)
PURY-P450YSLM-A(-BS)
PURY-P500YSLM-A(-BS)
PURY-P550YSLM-A(-BS)
PURY-P600YSLM-A(-BS)
PURY-P650YSLM-A(-BS)
PURY-P700YSLM-A(-BS)
PURY-P750YSLM-A(-BS)
PURY-P800YSLM-A(-BS)
PURY-P850YSLM-A(-BS)
PURY-P900YSLM-A(-BS)
PURY-EP-YLM
PURY-EP200YLM-A(-BS)
PURY-EP250YLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP450YLM-A(-BS)
PURY-EP500YSLM-A(-BS)
PURY-EP550YSLM-A(-BS)
PURY-EP600YSLM-A(-BS)
PURY-EP650YSLM-A(-BS)
PURY-EP700YSLM-A(-BS)
PURY-EP750YSLM-A(-BS)
PURY-EP800YSLM-A(-BS)
PURY-EP850YSLM-A(-BS)
PURY-EP900YSLM-A(-BS)
38
Unit Combination
Hz
-
-
-
-
PURY-P200YLM-A(-BS)
PURY-P200YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P200YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P250YLM-A(-BS)
PURY-P300YLM-A(-BS)
50/60
PURY-P300YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P300YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P350YLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P450YLM-A(-BS)
PURY-P400YLM-A(-BS)
PURY-P450YLM-A(-BS)
PURY-P450YLM-A(-BS)
Unit Combination
Hz
-
-
-
-
-
-
PURY-EP250YLM-A(-BS)
PURY-EP250YLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP250YLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP300YLM-A(-BS)
50/60
PURY-EP350YLM-A(-BS)
PURY-EP300YLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP350YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP450YLM-A(-BS)
PURY-EP400YLM-A(-BS)
PURY-EP450YLM-A(-BS)
PURY-EP450YLM-A(-BS)
Symbols: MCA (Max Circuit Amps)
Power
Units
Compressor
supply
Voltage
Output
Volts
MCA(A)
SC(A) Output(kW)
range
(kW)
16.1
5.6
20.5
6.9
25.4
8.1
30.6
10.5
5.6
30.8
5.6
6.9
35.5
5.6
6.9
40.9
6.9
8.1
45.8
6.9
380
8.1
Max:456V
400
52.0
Min:342V
8.1
415
10.5
55.5
8.1
10.5
61.9
10.5
10.9
66.7
10.5
10.9
71.6
10.9
12.4
73.7
10.9
12.4
76.8
12.4
Power
Units
Compressor
supply
Voltage
Output
Volts
MCA(A)
SC(A) Output(kW)
range
(kW)
16.1
5.6
19.9
6.9
23.6
8.1
30.6
10.5
31.7
10.9
37.4
12.4
6.9
39.9
6.9
8.1
43.6
6.9
8.1
48.1
380
8.1
Max:456V
400
Min:342V
10.5
415
53.2
8.1
10.5
59.8
10.5
10.9
62.3
10.5
10.9
63.3
10.9
12.4
70.3
10.9
12.4
75.6
12.4
RLA (Rated Load Amps), SC (Starting Current)
FAN
RLA(A)(50/60Hz)
Cooling
8
0.92
10.0/9.5/9.1
11.0/10.4/10.1
8
0.92
13.3/12.7/12.2 14.6/13.8/13.3
8
0.92
16.5/15.7/15.1 18.1/17.2/16.6
8
0.92
21.4/20.3/19.6 21.8/20.8/20.0
8
0.92
20.8/19.8/19.1 22.0/20.9/20.2
8
0.92
8
0.92
23.9/22.7/21.8 25.3/24.0/23.2
8
0.92
8
0.92
27.6/26.2/25.3 29.2/27.7/26.7
8
0.92
8
0.92
31.6/30.0/28.9 32.7/31.0/29.9
8
0.92
8
0.92
35.2/33.5/32.3 37.1/35.2/33.9
8
0.92
8
0.92
38.7/36.8/35.4 39.6/37.6/36.2
8
0.92
8
0.92
44.2/42.0/40.5 42.9/40.7/39.3
8
0.92
8
0.92
47.6/45.2/43.6 43.0/40.8/39.4
8
0.92
8
0.92
51.1/48.5/46.8 42.0/39.9/38.5
8
0.92
8
0.92
52.6/49.9/48.1 48.1/45.7/44.1
8
0.92
8
0.92
53.2/50.6/48.7 54.8/52.0/50.1
8
0.92
FAN
RLA(A)(50/60Hz)
Cooling
8
0.92
9.2/8.7/8.4
10.8/10.2/9.9
8
0.92
12.2/11.6/11.2 14.2/13.5/13.0
8
0.92
15.5/14.7/14.2 16.8/15.9/15.4
8
0.92
21.2/20.1/19.4 21.8/20.7/19.9
8
0.92
21.2/20.1/19.4 22.6/21.4/20.7
8
0.92
25.0/23.7/22.9 26.7/25.4/24.5
8
0.92
25.2/24.0/23.1 28.5/27.1/26.1
8
0.92
8
0.92
29.2/27.8/26.8 31.1/29.5/28.5
8
0.92
8
0.92
32.9/31.3/30.2 34.3/32.6/31.4
8
0.92
8
0.92
37.3/35.4/34.1 38.0/36.1/34.7
8
0.92
8
0.92
43.8/41.6/40.1 42.6/40.5/39.0
8
0.92
8
0.92
43.8/41.6/40.1 44.5/42.3/40.7
8
0.92
8
0.92
43.7/41.5/40.0 45.2/42.9/41.4
8
0.92
8
0.92
48.0/45.6/44.0 50.2/47.7/45.9
8
0.92
8
0.92
52.2/49.6/47.8 54.0/51.3/49.4
8
0.92
AN1 2nd
Heating
Heating