D
Specifications

SFF Specifications

Table D-1
Specifications
Chassis (in the desktop position)
Height
Width
Depth
Approximate Weight
Weight Supported (maximum distributed load in desktop position)
Temperature Range
Operating
Nonoperating
NOTE:
Operating temperature is derated 1.0° C per 300 m (1000 ft) to 3000 m (10,000 ft) above sea level; no direct sustained
sunlight. Maximum rate of change is 10° C/Hr. The upper limit may be limited by the type and number of options installed.
Relative Humidity (noncondensing)
Operating
Nonoperating (38.7°C max wet bulb)
Maximum Altitude (unpressurized)
Operating
Nonoperating
Power Supply
Operating Voltage Range
Rated Voltage Range
Rated Line Frequency
Operating Line Frequency
Standard Efficiency
80 PLUS Bronze
80 PLUS Platinum
Rated Input Current
Current Leakage (NFPA 99)
3.74 in
95 mm
10.63 in
270 mm
11.65 in
296 mm
9.92 lb
4.5 kg
77 lb
35 kg
50° to 95°F
10° to 35°C
-22° to 140°F
-30° to 60°C
10-90%
10-90%
5-95%
5-95%
16,404 ft
5000 m
50,000 ft
15,240 m
90-264 VAC
100-240 VAC
50-60 Hz
47-63 Hz
200W active PFC
200W active PFC; 82/85/82% efficient at 20/50/100%
load (115V)
200W active PFC; 90/92/89% efficient at 20/50/100%
load (115V)
200W active PFC; 91/93/90% efficient at 20/50/100%
load (230V)
3.5A/Max
< 275 μA
SFF Specifications 143