BEKOMAT
®
12, 12 CO, 12 CO PN63
7.2 Connection work
For connection work to be carried out, the following prerequisites must be fulfilled and the preparatory tasks must have
been completed.
Tools
•
Stripping tool
•
Crimping tool for wire-end ferrules
•
Screwdriver - cross-head size 2.5
mm (0.09")
•
Screwdriver - flat-blade
size 2.5 mm (0.09")
1.
Assembly must have been completed.
Protect the cables for the voltage supply of the BEKOMAT
2.
technical data.AC = 1 A (time-lag) recommended
DC = 1 A (time-lag) prescribed
In the case of AC voltage supply an accessible circuit breaker (e.g. power plug or switch) that shuts off all
3.
energised conductors must be installed close to the unit.
7.2.1 Voltage supply connection
7.2.1.1 Power control board AC
Illustration
3
26 | 64
Prerequisites
Material
•
3-wire cable for voltage supply 230 V
•
2-wire cable for voltage supply 24 V
•
2-wire cable for external test
•
2/3-wire cable for potential-free
contact
(depending on the application)
•
Wire end ferrules
Preparatory tasks
Description / explanation
4. Loosen the 4 pan-head screw [3] in the top
cover and unscrew the components of the cable
gland [5, 6, 7, 8].
5
6
7
8
Original installation and operation manual
Protective equipment
Always to be worn:
®
in accordance with the specifications in the