18/57
Assembly
6.3

Assembly of primary parts

Fastening screws
Frame size
ML3P03
M4 (DIN EN ISO 4762)
ML3P06
M5 (DIN EN ISO 4762)
ML3P11
M5 (DIN EN ISO 4762)
Dowels
Bosch Rexroth AG R911389762_Edition 04
To fasten the primary part, only new, unused screws must be
used.
Only use specified screws (see
Tighten all screws crosswise with the necessary tightening
torque - from inside to outside.
Lock screw connection with Loctite 243, for example (ob‐
serve the notes of the adhesive manufacturer).
When using dowels, ensure that they do not protrude more
than specified in the dimension sheets. The primary part
could be damaged.
After assembly, check if any foreign bodies exist between
primary and secondary part.
Screw size
Screw-in depths
max. 5 mm
min. 4.5 mm
max. 6 mm
Tab. 6-3:
Fastening screws with tightening torques for ML3P primary parts
Size primary part
ML3P03 ... 11
Tab. 6-4:
Dowels for ML3P primary part
Strength class
min. 4 mm
8.8
(with internal thread M3 for disassembly)
ML3 Self-Cooled Linear Motors
Fig.
6-3).
Tightening torque
(± 10 %)
3.1 Nm
6.1 Nm
6.1 Nm
Dowels (rust-free)
5h8