Digital Hall Unit - Bosch rexroth ML3 Operating Instructions Manual

Self-cooled linear motors
Hide thumbs Also See for rexroth ML3:
Table of Contents

Advertisement

ML3 Self-Cooled Linear Motors
6.6.2

Digital Hall unit

Distance di‐
mension
ML3P...
"Z"
03
8.4 mm
06
8.4 mm
11
9.4 mm
The preferred installation position of the Hall unit is at the slide at the front
end of the primary part with the cable outlet (see
aligned at the side of the coil unit. For further installation positions and infor‐
mation on commutation or calculation of parameter P-0-0509, see
For installation of the digital Hall unit, a spacer (see dimension
"Z") is required between the Hall unit and the contact surface of
the primary part.
*
For tolerances refer to dimension sheet in ML3 project planning
manual
Z
Dimensions for spacer thickness
Fig. 6-11:
Preferred installation position for the digital Hall unit
Rotation to the motion
Alignment to the side
axis [degrees]
of the primary part
0.5
Tab. 6-8:
Installation requirements of digital Hall unit
Screws
± 1 mm
M3
R911389762_Edition 04 Bosch Rexroth AG
27/57
Assembly
Fig.
6-11). The Hall unit is
Tab. 1-2
Tightening torque
Dowel
(+/- 10%)
pins
1.3 Nm
Ø 5 F8