2-10 General Description
Virtual LCD indications when STATUS lamp is flashing red
On-screen message
Proc 1 IERR
Proc 2 IERR
WDT Timeout
WDT Power Down
SMI Timeout
ErrPause in POST
DUMP Request !
Memory U-Err XX
Proc Missing
Proc1 Config Err
Proc2 Config Err
BB Mez1 PwFault
BB Mez2 PwFault
Proc1ThermalTrip
Proc2ThermalTrip
Proc1 Therm % 09
Proc2 Therm % 09
AmbientTempAlm09
AmbientTempAlm02
Description
An error was detected in CPU#1.
An error was detected in CPU#2.
Watchdog timer timeout error
occurred.
Forcibly powered off due to
watchdog timer timeout error.
A timeout error occurred while
the system management
interrupt process is in progress.
The system is waiting for key
entry due to serious POST error.
Under memory dump request.
An uncorrectable memory error
was detected. XX denotes the
DIMM slot number with 1-origin
that contains the failed DIMM.
No CPU is installed in slot
CPU#1.
The CPU installed in the CPU#1
slot is unsupported or its
combination is illegal.
The CPU installed in the CPU#2
slot is unsupported or its
combination is illegal.
An error was detected in power
circuit of mezzanine card
installed in Type I slot.
An error was detected in power
circuit of mezzanine card
installed in Type II slot.
Forced power-off occurred due to
a thermal error in CPU#1.
Forced power-off occurred due to
a thermal error in CPU#2.
A high temperature error was
detected in CPU #1.
A high temperature error was
detected in CPU #2.
A high temperature error was
detected in chassis.
A low temperature error was
detected in chassis.
Action
1. Turn off the power and then turn
it on again.
2. If an error message appears on
the POST screen, check the
message.
3. If no error message appears,
check the system by using the
Off-line Maintenance Utility.
Check the error message on the
POST screen.
Wait until dump collection
completes.
1. Check the installation status of
the DIMM.
2. Replace the DIMM.
Check the installation status of the
CPU.
Check if the installed CPU is
supported by the system.
Check the CPU combination, such
as the frequency of CPU#1 and
CPU#2.
1. Check the installation status of
the mezzanine card.
2. Replace the mezzanine card.
Check if the fans in the Blade
Enclosure work normally.
Check the heat sink of the CPU
blade.
Refer to the User's Guide of the
Blade Enclosure to make sure that
a sufficient number of fans are
installed.
Check if the fans and CPU blades
are installed in the correct locations.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.
Check if the ambient temperature of
the installation location satisfies the
operating conditions.