7. Check that the specification in the Z direction is met.
Measuring device: Monitor of unit alignment tool
0 ?40 μm
Specification:
If the specification is not met, align the display unit in the Z direction again (Refer to step 5). Then,
check that the specification in the Y direction described in step 6-(5) is met.
8. Save the data on the monitor of unit alignment tool. ([Data Save] button)
9. Stop the unit alignment tool ([Stop] button), then turn off the battery. Disconnect the two cords of the
unit alignment tool. You can disconnect whichever cords, USB cable or power cord, first.
t
The unit alignment tool can remain attached to the first unit until it is attached to the second unit.
The installation of the first display unit in the system is completed.
For details on the installation of the second or subsequent display units, proceed to "2-4-5. Installation of
Other Display Units".
2-18 (E)