Technical Data - Beko Drypoint ACC 4 Instruction/Technical Manual

Table of Contents

Advertisement

Section 9: Technical Data

Technical Data

Environmental Conditions
All dryers are designed to be safe under the following conditions:
Indoor use
Altitude up to 6560 ft.
Ambient temperature 41°F (5°C ) to 104°F (40°C)
Maximum RH 80% for temperatures up to 87.8°F (31°C), decreasing linearly to 50% RH at 104°F (40°C)
Mains supply voltage fluctuations not to exceed +/- 10% of nominal
Transient over voltage IEC 60664 Class II
Pollution degree 2, IEC 60664
For operation extended from the above conditions, please contact the manufacturer.
Excessive vibrations from external sources may cause failure of this product.
Reference Conditions
Measurement
Effective inlet pressure
Effective inlet temperature
Relative humidity of air at inlet
Pressure dewpoint, standard version
Specified Limitation for Operation
Measurement
Maximum inlet air pressure
Minimum inlet air pressure
Maximum ambient air temperature
Minimum ambient air temperature
Standard pressure dewpoint
Optional pressure dewpoint with application
of flow correction factor
Electrical supply voltage
42
Performance
101.5 psig
95°F
95%
-40°F
Performance
232 psig
58 psig
122°F
41°F
-40°F
-94°F
100 VAC to 240 VAC
Heatless Desiccant Dryers |
7 barg
35°C
-40°C
16 barg
4 barg
50°C
5°C
-40°C
-70°C
12 VDC to 24 VDC