Lenovo ThinkSystem D2 Manual page 166

Enclosure, modular enclosure, modular enclosure for 6u configuration and thinksystem sd530 compute node messages and codes reference
Hide thumbs Also See for ThinkSystem D2:
Table of Contents

Advertisement

1. Check Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
• FQXSFIO0008M: An intra-board UPI dynamic link width reduction has been detected on the link
between processor [arg1] port [arg2] and processor [arg3] port [arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
• FQXSFIO0009M: An inter-board UPI dynamic link width reduction has been detected on the link
between processor [arg1] port [arg2] and processor [arg3] port [arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Reboot the system.
2. If the problem persists, collect Service Data logs.
3. Contact Lenovo Support.
• FQXSFIO0010M: An Uncorrectable PCIe Error has Occurred at Bus [arg1] Device [arg2] Function
[arg3]. The Vendor ID for the device is [arg4] and the Device ID is [arg5]. The physical [arg6] number
is [arg7].
Severity: Error
User Action:
Complete the following steps:
1. Check Lenovo support site for an applicable device driver, firmware update, version of service
information for this product or other information that applies to this error. Load new device driver and
any required firmware updates.
2. If this device and/or any attached cables were recently installed, moved, serviced or upgraded.
a. Reseat adapter or disk and any attached cables.
b. Reload Device Driver.
c. If device is not recognized, reconfiguring slot to lower speed may be required. Gen1/Gen2/Gen3
settings can be configured via F1 Setup -> System Settings -> Devices and I/O Ports ->PCIe
Gen1/Gen2/Gen3/Gen4 Speed Selection, or the OneCLI utility.
d. If a PCIe error has also been reported on a second slot within the same node, please ensure steps
a, b, and c above are also performed for that adapter or disk before proceeding.
3. If the problem persists, collect Service Data logs.
4. Contact Lenovo Support.
• FQXSFIO0011M: A PCIe parity error has occurred on Bus [arg1] Device [arg2] Function [arg3]. The
Vendor ID for the device is [arg4] and the Device ID is [arg5]. The Physical slot number is [arg6].
Severity: Error
162
ThinkSystem D2 Enclosure, Modular Enclosure, Modular Enclosure for 6U Configuration and ThinkSystem SD530 Compute
Node Messages and Codes Reference

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

7x207x217x22

Table of Contents