Lenovo ThinkSystem D2 Manual page 170

Enclosure, modular enclosure, modular enclosure for 6u configuration and thinksystem sd530 compute node messages and codes reference
Hide thumbs Also See for ThinkSystem D2:
Table of Contents

Advertisement

5. Contact Lenovo Support.
• FQXSFIO0022J: PCIe Link Width has degraded from [arg1] to [arg2] in physical [arg3] number
[arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFIO0023J: PCIe Link Speed has degraded from [arg1] to [arg2] in physical [arg3] number
[arg4].
Severity: Warning
User Action:
Complete the following steps:
1. Check the log for a separate error related to an associated PCIe device or NVME disk and resolve
that error.
2. Check the Lenovo support site for an applicable service bulletin or firmware update for the system or
adapter that applies to this error.
3. Check the system spec to make sure that the PCIe device or NVME disk is installed in the compatible
PCIe slot or bay and a compatible cable is used. If not, performance of this device might be
impacted.
4. If the problem persists, collect Service Data logs.
5. Contact Lenovo Support.
• FQXSFMA0001I: DIMM [arg1] Disable has been recovered. [arg2]
Severity: Info
User Action:
Information only; no action is required.
• FQXSFMA0001M: DIMM [arg1] has been disabled due to an error detected during POST. [arg2]
Severity: Error
User Action:
Complete the following steps:
1. Reseat the affected DIMM (Note: The event Log might contain a recent FQXSFMA0011I event
denoting detected change in DIMM population that could be related to this problem.)
2. Boot to F1 setup and enable the DIMM (For AMD, do not need to enable DIMM in Setup). Reboot the
system.
3. Update UEFI firmware to the latest version.