Siemens RUGGEDCOM RX1501 Installation Manual page 11

Simatic net rugged multi service platforms
Hide thumbs Also See for RUGGEDCOM RX1501:
Table of Contents

Advertisement

Introduction
1.2 Description
1
2
3
4
5
6
7
8
Figure 1.1
Management Port
RS-232 Serial Console Port
Utility USB Port
Lamp Test/Alarm Cut-Off (LT/
ACO) Button
Power Status LEDs
Port Status LEDs
Alarm Indicator LED
Compact Flash Card Port
2
1
Management Port
RS232 Serial Console Port (DB9)
Utility USB Port
Port Status LEDs
Power Status LEDs
Alarm Indicator LED
Lamp Test/Alarm Cut-Off (LT/ACO) Button
Compact Flash Card Port
RUGGEDCOM RX1501
4
6
7
2
3
5
This 10/100Base-T Ethernet port is used for system management
that is out-of-band from the switch fabric.
The serial console port is for interfacing directly with the device
and accessing initial management functions. For information
about connecting to the device via the serial console port, refer to
"Connecting to the Device (Page
Use the USB port to upgrade the RUGGEDCOM RX1501 software
or install files, such as configuration files and feature key files. For
more information, refer to the "RUGGEDCOM ROX Configuration
Manual" for the RUGGEDCOM RX1501.
This button performs two functions:
Press and hold this button to test all indicator LEDs
Press and release this button to acknowledge an active alarm
Indicates the status of the power modules.
I = The power module is receiving power
O = The power module is supplying power
Indicates when ports are active.
Green = OK
Orange = Warning alert
Red = Configuration error
Indicates when an alarm condition exists.
Green = Alarms cleared/acknowledged
Red = Alarm
Houses the CompactFlash (CF) card that contains active and backup
installations of RUGGEDCOM RUGGEDCOM RX1501, along with
the configuration database and other system data. For more
information, refer to
"Accessing the CompactFlash Card (Page
23)".
8
21)".
Installation Manual, 04/2022, C79000-G8976-1054-22
RUGGEDCOM RX1501