2.3 Connecting a Probe to the User System
Connect a probe to the user system.
The type of connection between a probe and the user system varies depending on the configuration
of the probe to be used. Table 3 summarizes the applicable probe configurations.
Cable used
Probe cable
Flat cable
* : The shape of the header connector varies depending on the product.
Note : Before connecting the adapter board to the user system using a probe, remove the mass-production
MCU from the user system.
■ Connecting to the user system (using a probe cable)
Connect the corresponding probe cable of the mass-production MCU package to be used to the con-
nector of the user system, as shown in Figure 4.
See the probe cable operation manual of the relevant product for information on how to connect the
connector of the probe cable header.
6
Probe configuration
Probe cable
Flat cable + probe header
Flat cable
Example: IC socket, connector (NQPACK)
Figure 4 Connecting to the user system (using a probe cable)
Table 3 Probe configurations
Method of connecting to the user system
Connect the connector* of the probe cable header to the
connector* of the user system.
Connect the connector* of the probe header to the con-
nector* of the user system.
Connect the connector of the flat cable to the connector
of the user system.
Probe cable
User system