Model:
Acceleration Voltage:
Display Area:
VERTICAL AXIS (CH1 and CH2)
Sensitivity:
Accuracy:
Attenuator:
Input Impedance:
Frequency Response:
x 1 mode:
5V/div range and
x 5 mode:
Risetime:
Signal Delay Time:
Crosstalk
Operating Modes:
Chop Frequency:
Channel Polarity:
A Maximum Input
^
Voltage:
Non-Distorted Maximum
Amplitude:
Bandwidth Limiting:
4

SPECIFICATIONS

150HTM31
Rectangular, with internal
graticule
16 kV
8 x 10 div
(1 div = 10 mm)
5 mV/div to 5 V/div
( x 1 mode)
1 mV/div to 1 V/div
( x 5 mode)
± 3 % ( 1 0 ~ 3 5 ° C )
± 5 % ( 0 ~ 5 0 ° C )
10 steps, 5 mV/div to 5 V/div
in 1-2-5 sequence.
Vernier control for fully ad-
justable sensitivity between
steps.
1 M Q ± 2 % , approx. 22pF
DC; DC to 100 MHz, - 3 dB
A C ; 5 Hz to 100 MHz, - 3 d B
DC; DC to 50 MHz, - 3 dB
A C ; 5 Hz to 50 MHz, - 3 d B
3.5 nsec or less (100 MHz)
Approx. 10 nsec on the
CRT screen.
—40 dB minimum
C H 1 ; single trace
C H 2 ; single trace
ADD; CH1 + C H 2 added as a
single trace.
ALT; dual trace, alternating
CHOP; dual trace, chopped
Approx. 2 5 0 kHz
Normal or inverted, channel
2 only inverted.
500 Vp-p or 2 5 0 V (dc + ac
peak)
More than 8 div (dc to
100 MHz)
Vertical system bandwidth
with the 20 MHz BW push
button switch pushed is ap-
proximately 20 MHz
HORIZONTAL AXIS (Input thru CH2)
Operating Modes:
Sensitivity:
Accuracy:
Input Impedance:
Frequency Response
X-Y Phase Difference:
A Maximum Input
Voltage:
SWEEP
Type:
A;
ALT;
B DLYD;
X-Y;
Sweep Time: A;
B;
Accuracy:
Sweep Magnification:
Linearity:
Holdoff:
Trace Separation:
Delay Method (B MODE):
With HORIZ. DISPLAY
switch, X - Y operation is
selectable
C H 1 ; Y a x i s
C H 2 ; X axis
Same as vertical axis (CH2)
Same as vertical axis (CH2)
Same as vertical axis (CH2)
DC; DC to 5 MHz, —3 dB
A C ; 5 Hz to 5 MHz, - 3 dB
3 ° or less at 100 kHz
Same as vertical axis (CH2)
A sweep
A sweep (intensified for
duration of B sweep) and B
sweep (delayed sweep)
alternating
Delayed sweep
X - Y oscilloscope
20 ns/div to 0.5 s/div in 2 3
ranges, in 1-2-5 sequence.
Vernier control provides fully
adjustable sweep time bet-
ween steps.
20 ns/div to 50 ms/div in
20 ranges, in 1 -2-5 se-
quence.
± 3 % ( 1 0 ~ 3 5 ° C )
± 6 % ( 0 ~ 5 0 ° C )
x 10 (ten times)
± 5 % ( 1 0 ~ 3 5 ° C )
± 7 % ( 0 ~ 5 0 ° C )
± 3 % (on 20 ns/div to
0.5 s/div)
± 5 % ( x 1 0 MAG)
Continuously variable from
NORM to more than five
times (MAX)
B sweep can be separated
downward from A sweep up
to approx. 4 divisions, con-
tinuously adjustable.
Continuous delay (STARTS
AFTER DELAY), Trigger
delay (TRIGGER)