CASSETTE TYPE AIR CONDITIONER Operation & Installation Manual No.0010576262 Please read this operation manual before using the air conditioner. Please keep this manual carefully and safely. AB482XCAAA AB242XCAAA...
Damaged air conditioners are not to be put into operation. In case of doubt, consult your supplier. Use of the air conditioner is to be carried out in strict compliance with the relative instructions set forth in the User's Guide.
Page 4
Do not obstruct or cover the ventilation grille of the air conditioner. Do not put fingers or any other things into the inlet/outlet and swing louver. Do not allow children to play with the air conditioner.
Page 5
Cautions Safety cautions Carefully read the following information in order to operate the airconditioner correctly. Below are listed three kinds of Safety Cautions and Suggestions. WARNING! Incorrect operations may result in severe consequences of death or serious injuries. CAUTION! Incorrect operations may result in injuries or machine damages; in some cases may cause serious consequences.
Cautions Conditioner should not be used for any other purpose other than airconditioning. Don't use air-conditioner for any other special purposes, e.g. the preservation and protection of food, animals, plants, pecision apparatus as well as work of art, otherwise the qualities of these stuffs may be damaged.
Introduction to Spare Parts Discharge unit (built in) In cooling operation, to discharge the water from inside the room. Outlet Air filter (located in the suction grill) Suction grill Drain Hose Swing fender (located in the outlet) Refrigerant pipe Cable line Earthing line...
Parts and Functions Operation CLOCK Used to set correct time. TIMER Used to select TIMER ON, TIMER OFF, TIMER ON/OFF. TIME Used to set clock and timer setting. Power ON/OFF Used for unit start and stop. Cautions: On cooling only unit, heating mode is not available.
Parts and Functions Operation SLEEP AUTO FAN SPEED TIMER ON TIMER OFF CLOCK Clock set When unit is started for the first time, clock should be adjusted as follows: Press CLOCK button, "AM"or "PM" flashes. Buttons and display of the wire controller. Remote control COOL HEAT...
Page 10
Operation The air conditioner has the function of POWER FAILURE RESUME. Fan operation Enjoy yourself by just a gentle press. (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display. (Not Timer setting) Power indicator lights up.
Page 11
Operation AUTO RUN, COOL,HEAT and DRY operation Recommendations Use COOL in summer. Use HEAT in winter. Use DRY in spring,autumn and in damp climate. (1) Unit start Press ON/OFF button, unit starts. Previous operation status appears on display (Not Timer setting). Power indicator lights up. (2) Select operation mode Press MODE button.
Operation TIMER operation Set Clock correctly before starting Timer operation. You can let unit start or stop automatically at following time: Before you wake up in the morning, or get back from outside or after you fall asleep at night. TIMER ON/OFF (1)After unit start, select your desired operation mode.
Page 13
Operation TIMER ON-OFF (1)After unit start, select your desired operation mode Operation mode will be displayed on LCD. Power indicator lights up. (2) Press TIMER button to change TIMER mode Every time the button is pressed, display changes as follows: Select (3)Time setting for TIMER ON Press TIME button.
Page 14
Operation Comfortable Sleep At night, before going to bed you can press down the SLEEP button on the controller and the air- conditioner will run by the comfortable sleeping mode to make you sleep more comfortable. In cooling, dehumidifying mode In heating mode Note: In AUTO mode, unit will run in SLEEP function according to the operation mode.
Page 15
Notes: When a power failure suddenly occurs during the air conditioner is working after the power failure compensation is set, if the air conditioner will not be used for a long time, please cut off the power supply to prevent its operation from being resumed after the power is supplied again, or press the "Switch On/Off"...
Maintenance [Clean air filter] NOTE When having to clean, don't dismantle air-filter,otherwise may cause faults. In the environment where there is too much dust, air filter should be cleaned for more times. (about half a year one time) 1. Open inlet grill Press the elliptical "PUSH"...
Page 17
Maintenance 2. Take off air-filter 3. Take of inlet grill 4. Clean CAUTION! NOTE When the filter too much dust To spray the special detergent for vent fan or utensils. 5. Install inlet grill see 3 6. Install air filter see "Clean air filter"...
Page 18
Stop operation and turn off the power supply switch .Electric power is consumed even the air conditioner is in stop. Clean the air filter, indoor unit and outdoor unit,and cover the unit with dustcoat.
When the air conditoner is started, when the compressor starts or stops during operation or when the air conditioner is stopped,it som- etimes sounds ì Bi- Bi-î or ì Godo-Godoî . It is the flowing sound of the refrigerant , not a malfunction.
Page 20
During heating,indoor fan is still running even unit is stopped. Please check the following things about your air conditioner before making a service call. Is the power supply switch on ? Power supply switch is not in ON position.
Insufficient cooling Sunlight direct into the room ? When the air conditioner does not operate properly after you have checked the above-mentioned items or when following phenomenon is observed,stop the operation of the air conditioner and contact your sales dealer.
Customer Need-to-know Customer Need-to-know Please install the air conditioner according to the requirements specified in this manual to ensure the air conditioner work well. Be careful not to scratch the surface of the case during moving the air conditioner. Please keep the installation manual for future reference when maintenance and changing installation place.
Installation Procedure Installation Please ask the dealer or specialist to install, never try by the users themselves. After the installation please be sure of the following conditions. Please call dealer to install the air-conditioner. Incorrect installation may cause water leaking, shock and fire hazard. Air-conditioner can't be installed in the envi- ronment with inflammable gases because the inflammable gases near to air-conditioner may...
Page 24
Installation Procedure To ensure proper installation, read "Cautions" carefully before working. After CAUTIONS: installation, start the unit correctly and show customers how to operate and maintain the unit. Meanings of Warning and Cautions: Warning! Serious injury or even death might happen, if it is not observed. Caution! Injury to people of damages to machine might happen, if it is not observed.
Installation Procedure Installation tools The installation tools listed in the following sheet can be used as required. 1. Screw driver 2. Hacksaw 3. Drill with a diameter of 60mm 4. Inner hexagon spanner,shifting spanner 5. Spanner (14, 17, 19,24,27mm) 6. Pipe cutter 7.
Installation Procedure 1. BEFORE INSTALLATION Determine the way to carry unit to installation place. Don't remove packing until unit reaches installation place. If unpacking is unkavoidable, protect unit properly. 2. SELECTION OF INSTALLATION PLACE (1) Installation place shall meet the following and agreed by customers: Place where proper air flow can be ensured.
Page 27
Installation Procedure 3. PREPARATION FOR THE INSTALLATION (1) Position of ceiling opening between unit and suspending bolt. (Distance between suspending bolts) 840(Indoor unit) 890(Ceiling opening) 950(Ornament panel) (2) Cut an opening in ceiling for installation if necessary. (when ceiling already exists.) Refer to paper pattern for dimension of ceiling hole.
Page 28
Installation Procedure 4. INSTALLATION OF INDOOR UNIT In the case of new ceiling (1) Install unit temporally Put suspending bracket on the suspending bolt. Be sure to use nut and washer at both ends of the bracket. As for the dimensions of ceiling hole, see paper pattern. Ask your real estate dealer for details. Center of the hole is marked on the paper pattern.
Installation Procedure 5. REFRIGERANT PIPING Outdoor is precharged with refrigerant. Be sure to see the Fig.1, when connecting and removing piping from unit. For the size of the flare nut, please refer to Table 1. Apply refrigerant oil at both inside and outsid of l flare nut. Tighten it band tight 3-4 turns then tighten it. Use torque specified in Table 1.
Page 30
Installation Procedure (2) Check if water drainage is smooth after installation. Charge, through air outlet or inspecting hole, 1200ccd water to see water drainage. After wiring Check water drainage in cooling operation. When wiring is not complete Remove cover of control box, short connect "CHECK" terminal of the indoor unit, which is on the uper part of indoor unit PCB.
Installation Procedure 7. WIRING All supplied parts. materials and wiring operation must in appliance with local code and regulations. Use copper wire only. When make wiring, please refer to wiring diagram also. All wiring work must be done by qualified electricians. A circuit breaker must be installed, which can cut power supply to all system.
Page 32
Installation Procedure 2. Install wire controller (1) For exposed installation, use 2 wood screws (accessory). (2) For recessed installation, use 2 wood screws (accessory). Note Try as far as possible a flat surface for installation. Don't use excessive force when tightening screws, or lower part might got deformed. 3.
Page 33
Installation Procedure Hint Tread surface of the terminal well so that shielding may not contact other part. 4. Replace the upper part of wire controller Be careful not to press the wiring. Hint 1. Switch box and cord for wiring are not supplied. 2.
Page 34
Installation Procedure 2. Mounting on high ceiling (1) Ornament panel can be mounted on ceiling as high as 3 m. (2) Please install pad as accessary. Cut open the pad along cutting ling. Use part a only and discard part b . (Refer to Fig. 4) Install part a of the pad on the place shown in Fig.