Kenwood CS-1022 Instruction Manual page 11

Hide thumbs Also See for CS-1022:
Table of Contents

Advertisement

C S - 1 0 2 2 , 1 0 2 1 , 1 0 1 2
©
GND terminal/binding post.
Earth and chassis ground.
(0)
PROBE A D J .
Provides approximately 1 kHz, 0.5 Volt peak-to-peak
square wave signal. This is useful for probe compen-
sation adjustment.
(g)
TRACE ROTATION
Electrically rotates trace to horizontal position.
Strong magnetic fields may cause the trace to be
tilted.
The degree of tilt may vary as the scope is moved
from one location to another. In these cases, adjust
this control.
( O D
FOCUS
Adjusts the trace for optimum focus.
(0)
INTENSITY
Clockwise
rotation
of this
brightness of the trace.
®
ASTIG
Astigmatism
adjustment
roundness when used in conjunction with FOCUS and
INTENSITY controls. Very little readjustment of this
control is required after initial adjustment.
©
EXT TRIG INPUT Jack
Input terminal for external trigger signal.
When SOURCE switch is selected in EXT position, the
input signal at the EXT TRIG INPUT jack becomes the
trigger.
@
LEVEL/PULL SLOPE ( - )
LEVEL:
Trigger level adjustment determines point
on waveform where sweep starts.
When COUPLING switch is selected in
VIDEO-FRAME or LINE, the trigger level ad-
justment has no effect.
SLOPE:
+ equals most positive point of triggering
and —equals most negative point of trigger-
ing. Push-pull switch selects positive or
negative slope.
Sweep is triggered on negative-going slope
of sync waveform w i t h switch pulled out.
control
increases
the
provides
optimum
spot
CS-1020, 1 0 1 0
(IJ)
GND terminal/binding post.
Earth and chassis ground.
©
PROBE A D J .
Provides approximately 1 kHz, 0.5 Volt peak-to-peak
square wave signal. This is useful for probe compensa-
tion adjustment.
©
TRACE ROTATION
Electrically rotates trace to horizontal position.
Strong magnetic fields may cause the trace to be
tilted.
The degree of tilt may vary as the scope is moved from
one location to another. In these cases, adjust this
control.
@>
FOCUS
Adjusts the trace for optimum focus.
(0)
INTENSITY
Clockwise
rotation
of
brightness of the trace.
(§)
ASTIG
Astigmatism
adjustment
roundness when used in conjuction w i t h FOCUS and
INTENSITY controls. Very little readjustment of this
control is required after initial adjustment.
(fj)
EXT TRIG INPUT Jack
Input terminal for external trigger signal and external
horizontal input terminal for X-Y operation.
When SOURCE switch is selected in EXT position, the
input signal at the EXT TRIG INPUT jack becomes the
trigger.
@
LEVEL/ PULL SLOPE ( - )
LEVEL:
Trigger level adjustment determines point
on waveform where sweep starts.
When COUPLING switch is selected in
VIDEO-FRAME or LINE, the trigger level ad-
justment has no effect.
SLOPE:
+ equals most positive point of triggering
and —equals most negative point of trigger-
ing. Push-pull switch selects positive or
negative
slope.
negative-going slope of sync
with switch pulled out.
this
control
increases
the
provides
optimum
spot
Sweep
is triggered
on
waveform
11

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-1021Cs-1012Cs-1020Cs-1010

Table of Contents