Features - Kenwood CS-1022 Instruction Manual

Hide thumbs Also See for CS-1022:
Table of Contents

Advertisement

• Vertical axis has high sensitivity and wide bandwidth
and especially covers fully specified frequency response
at 2mV/div for all models.
C S - 1 0 2 2 , 1021 ;
Dual Trace
1 mV/div
2mV/div
C S - 1 0 1 2 ;
Dual Trace
1 mV/div
2mV/div
C S - 1 0 2 0 ;
Single Trace
1 mV/div
2mV/div
C S - 1 0 1 0 ;
Single Trace
1 mV/div
2mV/div
• Vertical sensitivity range is selectable from 1 mV/div t o
5V/div w i t h rotary switch continuously.
• Time base permits the high sweep speed.
C S - 1 0 2 2 , 1 0 2 0 ; 20nsec/div ( x 10 MAG)
C S - 1 0 2 1 , 1 0 1 2 , 1 0 1 0 ; 50nsec/div ( x 1 0 MAG)
• Vertical sensitivity error and sweep rate error are ± 3 %
and accurate measurements are provided.
• The 1 5 0 m m rectangular CRT w i t h internal graticule
provides high brightness and accurate measurements,
free of parallax error.
C S - 1 0 2 2 , 1 0 2 0 ; domed mesh type CRT w i t h post-
deflection
acceleration
phosphors (acceleration voltage; 6 kV).
C S - 1 0 2 1 , 1 0 1 2 , 1 0 1 0 ; high brightness CRT (acce-
leration voltage; 2 kV).

FEATURES

: DC to 10 MHz, - 3 dB
: DC to 2 0 MHz, - 3 dB
: DC to 7 MHz, - 3 dB
: DC t o 10 MHz, - 3 dB
: DC to 10 MHz, - 3 dB
: DC to 2 0 MHz, - 3 dB
: DC to 7 MHz, - 3 dB
: DC to 10 MHz, - 3 dB
and
high
brightness
For convenience in making rise time measurements, the
0 % , 1 0 % , 9 0 % and 1 0 0 % levels are marked on the
graticule scale of the CRT.
• Trace rotation is electrically adjustable from the front
panel.
By SCALE ILLUM control, the waveform is easy observ-
ed in the dark and the photograph of the waveform is
easy provided. (Except CS-1021)
• Selectable AUTO FREE RUN function provides sweep
without trigger input signal.
• The FRAME-LINE switch provides selection of sync
pulse for sweep triggering from small amplitude to large
amplitude without adjusting when viewing composite
video waveforms.
For
C S - 1 0 2 2 ,
1 0 2 1
automatically provides the trigger signal w i t h TRIG
SOURCE and V. MODE switches.
• X-Y operation is easy provided by one-touche.
C S - 1 0 2 2 , 1 0 2 1 , 1 0 1 2 ; CH1
C S - 1 0 2 0 , 1 0 1 0 ; VERT INPUT
EXT TRIG INPUT
• CS-1022 and 1 0 1 2 are provided w i t h CH1 OUTPUT
terminal to monitor input signal of C H 1 .
• CS-1020 and 1 0 1 0 are provided w i t h VERT OUTPUT
terminal t o monitor input signal of VERT INPUT.
and
1 0 1 2 ,
vertical
mode
Y axis,
CH2
X axis
Y axis
X axis
3

Advertisement

Table of Contents
loading

This manual is also suitable for:

Cs-1021Cs-1012Cs-1020Cs-1010

Table of Contents