■ Trouble shooting
If an overvoltage trip occurs during deceleration of the stop position retaining control, make the value of [F362:
PID1 proportional gain] smaller. The deceleration time will become longer.
Note 1
2
2. 4
Dancer control is selected for dancer positioning control of winder system.
[F359: PID control1]
9
■ System image
2. PID control selection
[dEC: Deceleration time 1] setting is invalid during easy positioning PID control.
Output frequency (Hz)
Acceleration
Output frequency (Hz)
Acceleration

Dancer control

= "4: Dancer control" (Plus characteristic)
Inverter
Speed reference
0-10V input, etc
Overvoltage trip
(during deceleration)
[OP2] or [OP3]
Decrease
[F362: PID1 proportional gain]
Deceleration
Dancer detection value
4-20mA input, etc
Inverter
2-8