1. Features
1
Easy and Low-Cost Measurement
■Simple Measurement/Installation
 The built-in LCD screen enables the settings, measurements, and displays required for
 measuring energy with a single unit.
■Product Lineup that Provides Easy Equipment Selection
This measuring unit lineup consists of a "High Performance Model" and a "Standard Model".
High Performance Model: For customers who want to perform harmonic measurements, alarm monitoring,
 ① 
upper/lower limits monitoring, alarm output and pulse input/output, in addition to the Standard Model features
Standard Model: For customers who "want to start measuring energy in a simple and low-cost manner".
 ② 
■Specialized Cable is Not Required
You can use a general-purpose cable between the measuring unit and split current sensor!
Cost can be reduced because no specialized cable is required.
  * EMU2-CB-Q5B(-4W) is necessary if using a split 5A current sensor.
  * Refer to "Wiring Precautions" on p. 26 for information about general-purpose cables.
High Performance Model
EMU4-HD1-MB
High Performance Model
2
MODBUS
 Providing MODBUS
 with the functions listed below, and use it for energy management and as a system terminal.
Host systems (such as PLC, etc.)
 ①
Data Acquisition Software (EMU4-SW1)*
 ②
Display device (GOT)
 ③
  *1: Data Acquisition Software (EMU4-SW1) can be downloaded for free from the Mitsubishi Electric website.
   *2: A sample GOT screen can be downloaded for free from the Mitsubishi Electric website. (GT14**-Q, GT1030)
Energy Measuring Unit
*3: A unit compatible with MODBUS
3
・440V direct input
  (Three-phase 3-wire compatible)
・277V/480V direct input 
  (Three-phase 4-wire compatible)
・Measures harmonic current, 
 voltage, etc.
・Pulse input/output
・Contact input/output
RTU   ( RS485 )   C ommunication as Standard Equipment
®
RTU (RS485) communication as standard equipment allows you to connect
®
   to Special Applications on p.11
1
2
Host System
MODBUS
®
RTU
(RS485)
Communication
Data Acquisition 
software
Display Device
 (GOT)
 RTU (RS485) communication is required if connecting with a PLC.
®
Standard Model
You can measure all types of 
energy including power use, 
voltage and current.
Displayed on main unit of
measuring unit.
You can use the front panel
operating switches
to specify settings
and change the display.
MELSEC
MELSEC
FX Series*
Q Series*
3
Current Values Display
CSV File Output
GOT 1000 Series
EMU4-BD1-MB
Standard Model