Line Modules Booksize
3.2 Active line modules booksize internal air cooling
3.2.7

Technical specifications

Table 3-6
Technical specifications of active line modules
Internal air cooling
Rated power
Powers
Supply voltages:
Rated power (S1)*
power rating
(S6-40%)
Peak infeed power
rating
Regenerative feedback:
Continuous feedback
power rating
Peak feedback
power rating
Connection voltages:
Line voltage
Line frequency
Electronics power
supply
DC link
voltage
Overvoltage tripping
Undervoltage
tripping
Supply currents:
At 380 V
AC
At 480 V
/528 V
AC
AC
At 480 V; S6-40%
Peak current
(at 400 V
/480 V
)
AC
AC
Output currents at 600
V
:
DC
Rated current
at S6-40%
Peak current
DC link busbar current
capacity
24 V busbar
current capacity
Electronics current
consumption
Max. ambient temperature
without derating
Max. ambient temperature
with derating
3-14
6SL3130–
7TE21–
6AAx
kW
16
kW (Pn)
16
kW (Ps6)
21
kW (Pmax)
35
kW
16
kW
35
V
3AC 380 -10% to 3AC 480 +10% (-15% < 1 min)
Acrms
Hz
47 to 63 Hz
V
24 (20.4 – 28.8)
DC
V
510 - 750
DC
V
820 ± 2%
DC
V
360 ± 2%
DC
A
26
AC
A
21 / 19
AC
A
27
AC
A
54 / 45
AC
A
27
DC
A
35
DC
A
59
DC
A
100
DC
A
20
DC
A
See Cabinet Design
DC
°C
40
°C
55
7TE23–
7TE25–
6AAx
5AAx
36
55
36
55
47
71
70
91
36
55
70
91
58
88
46 / 42
70 / 64
60
92
107 / 89
139 / 116
60
92
79
121
117
152
100
200
20
20
40
40
55
55
Equipment Manual, (GH2), 04.2004 Edition, 6SL3097-2AC00-0BP0
7TE28–0AAx
7TE31–2AAx
80
120
80
120
106
145
131
175
80
120
131
175
128
192
102 / 93
152 / 139
134
201
200 / 166
267 / 222
134
200
176
244
218
292
200
200
20
20
40
40
55
55