CHAPTER 2 CONNECTIONS
Connect the external sense clip by the following procedure if it is used.
<1> Switch off the power of the target system first, then that of the IE-75001-R.
<2> Install the IC clip (commercially available) on the IC which is to be traced in the target system.
<3> Connect the external sense clip to the IC clip installed.
<4> Switch on the power to the IE-75001-R first, then that of the target system.
Figure 2-6. Connecting External Sense Clip
External Sense Clip
IC Clip
IC
Target System
Remark If an external sense clip is connected, be sure to use an IC clip insofar as possible. This helps prevent
faulty contact and improves operability.