3.4.2.7 Protocol set-up GE Medical System Senographe

Select Protocol (Shift-F1) when the SENOGRAP or SENO800T protocol is selected. This
will bring up the protocol set-up for the GE Medical System Senographe.
Define text for GE Senographe
Mode
Sub mode
Focus
Track
Filter
This window is used to define a number of text strings. The GE Medical System Senographe
sends a few parameters as 0 and 1, whereas they should be presented as texts instead.
This window is used to define those texts. For more detailed information, please refer to the
GE Medical System Senographe manual.
Each string may be up to 8 characters long. Use the up and down arrows to go to the row
below or above, and use Left- and Right soft-keys to select column.
Creating the picture that will be printed on the film is done in the same way as usual selecting
the COMM field type. NOTE! The communication protocol has to be set before setting up
the picture, otherwise the COMM field will display NONE.
Example
We want to create a COMM field that shall display the MODE. Create a new field and under
fielddefinition select Type COMM. The Senographe is sending 0, 1 or 2 as the MODE pa-
rameter and the Network ID Camera is translating it to a text according to the protocol set-
up above. In this case the texts are AOP for 0, AEC for 1 and Manual for 2. With reference
to this settings, the length should be set to 6 and Comm to MODE. This means that we have
to define the length of this COMM field to six characters maximum. Select Comm MODE will
link the Mode data to this field.
Fielddefinition
Type: Comm
Row:
Comm:
The field data do not include the unit (kV, mAs etc.). To add that, an F-text field with the ap-
propriate text has to be inserted after the COMM field. Create a new field and under field-
definition select Type F-text. Enter values for the row and column to place this field at a
position of your preference. Hint, use the Place function to position fields, see chapter 3.4.2
'Picture Win1/Win2'. Enter appropriate text under Fixed text.
Fielddefinition
Type: F-text
Row:
Fixed text:
Mode
October 2005
AOP
AEC
STD
CTS
SF
LF
RH
MO
RH
AL
Left
Right
Length:
56
Column:108
Mode
Previous
Next
56
Column: 84
20
NIC2-2 · Installation and Set-up Manual
Manual
DOSE
MO
Save
Field:01
4
Font: Small
Save
Field:02
Font: Small
Save
Triacon AB Sweden