Test 3: Measure Ac Voltage Output Of Each Stator Leg At Charging Rpm; Regulator / Rectifier (Non-Dynamix); Regulator Replacement - Polaris RZR XP Turbo Service Manual

2017-2018
Table of Contents

Advertisement

CONNECT
TEST
METER
LEADS TO:
Battery Charge
Y1 to Y2
Coil
Battery Charge
Y1 to Y3
Coil
Battery Charge
Y2 to Y3
Coil
NOTE
If there are any significant variations in ohm readings
between the three legs it is an indication that one of the
stator legs may be weak or failed.
TEST 2: RESISTANCE VALUE OF EACH STATOR
LEG TO GROUND
Measure the resistance value of each of the stator legs to
ground: Y1 to Ground, Y2 to Ground, Y3 to Ground.
Each test should measure:
CONNECT
TEST
METER
LEADS TO:
Battery Charge
Y1, Y2, or Y3
Coil
to Ground
NOTE
Any measurement other than Infinity (open) will indicate
a failed or shorted stator leg.
TEST 3: MEASURE AC VOLTAGE OUTPUT OF
EACH STATOR LEG AT CHARGING RPM
1. Set the selector dial to measure AC Voltage.
2. Start the engine and let it idle.
3. While holding the engine at a specified RPM,
separately measure the voltage across each 'leg' of
the stator by connecting the meter leads to the wires
leading from the alternator (Y1 to Y2, Y1 to Y3, Y2 to
Y3).
9928491 R04 - 2017-2018 RZR XP Turbo / XP4 Turbo Service Manual
© Copyright Polaris Industries Inc.
4. Refer to the following table for approximate AC
OHMS
Voltage readings according to RPM. Test each leg at
READING
the specified RPM in the table.
0.07 - 0.13 Ω
If one or more of the stator leg output AC voltage varies
significantly from the specified value, the stator may
0.07 - 0.13 Ω
0.07 - 0.13 Ω
RPM READING

REGULATOR / RECTIFIER (NON-DYNAMIX)

The regulator / rectifier is located under the hood in front
of the radiator.
If the regulator / rectifier case temperature exceeds 230°
F or 110° C, the unit will turn itself off to cool down. The
unit will turn on again after it has cooled down to at least
OHMS
212° F or 100° C. If it turns off, verify the cooling fins are
READING
clean, free from debris and that adequate airflow is
present.
Open Line
(Infinity)

REGULATOR REPLACEMENT

1. Remove the hood
2. Disconnect the two wiring harnesses
regulator.
ELECTRICAL
NOTE
need to be replaced.
AC VOLTAGE (VAC)
READING
1300
24 VAC ± 25%
3000
50 VAC ± 25%
5000
82 VAC ± 25%
q
.
w
going to the
11