Mounting - ABB C1300 Quick Start Manual

Advanced circular chart recorder
Hide thumbs Also See for C1300:
Table of Contents

Advertisement

C 1 3 0 0/A DVA N C E D C I R C U L A R C H A R T R E C O R D E R | C I/C 1 3 0 0 - E N R E V. C

4 Mounting

C1300 is designed for panel, wall-, pipe-, or panel-mounting.
For NEMA4X hose down rating please follow the installation
requirements shown:
1
Secure mounting
brackets (4) to case
Figure 3 Wall- and pipe-mounting
4
A – Wall-mounting
Position mounting
1
brackets to suit horizontal
pipe-mounting or vertical
pipe-mounting as required
Secure mounting
2
brackets to case using
bolts and washers
B – Pipe-mounting (optional)
2
Mark fixing centers on wall (4)
Secure instrument to
wall using suitable fixings
Secure using
4
two nuts and
washers
Drill suitable
holes (4)
3
2 ⅜ in. (60 mm) OD
horizontal or vertical pipe
3
Fit 'U' bolts
into brackets
5