Installing and connecting the device
3.2 Mounting the device
3.2.4

Mounting with latch fasteners

Requirement
● All packaging components and protective films have been removed from the device.
● The latch fasteners included in the accessory kit are ready to hand.
Procedure
Note
If the mounting seal is damaged or protrudes over the device, the degree of protection is not
guaranteed.
See also
Accessories (Page 15)
34
Proceed as follows:
1. Working from the front, insert
the device into the mounting
cut-out.
2. Insert the latch fasteners into
the recesses on the device.
Make sure they are in the
correct position, see chapter
Position of the mounting
clamps or latch fasteners
(Page 32).
3. Tighten the latch fasteners
using the setscrews. The
maximum permitted torque is
0.5 Nm.
4. Repeat steps 2 and 3 for all
latch fasteners.
5. Check the fit of the mounting
seal.