IPC Wizard functions

6.3 Standard calibration

6.3
Standard calibration
Procedure
1. Select "Start > Programs > UPDD > Settings".
2. Click the "Calibration" tab.
3. Activate the option "Use eeprom storage". For Touch Controllers with EEPROM, the
4. Click the button "Calibrate".
5. Quickly touch the corresponding selections one after the other.
6. Confirm all input prompts (arrows, or crosses in the center) until the complete screen has
Note
If the screen does not respond to touch as expected, check the controller selected under
"1." in "UPDD Console" and repeat the calibration. Only an active touch controller can be
calibrated. A removed touch controller is displayed in red.
If the accuracy of this 3-point calibration is not sufficient, you can clear the "Use eeprom
storage" option box and use the extended 25-point calibration instead.
54
The "UPDD Console" dialog box opens.
Select the touch controller of the device you want to calibrate in the header of the dialog.
option box is pre-selected.
The option box "Number of points" shows "3-point calibration".
The calibration screen is displayed in the selected display.
The entry is confirmed by a check mark, the next selection is displayed.
been calibrated.
Industrial Flat Panel IFP1500, IFP1900, IFP2200