Operating conditions

Mechanical and climatic conditions of use
The device is designed for use in locations protected from the effects of the weather. The
conditions of use meet the requirements for DIN IEC 60721-3-3:
● Class 3M3 (mechanical requirements)
● Class 3K3 (climatic requirements)
Use with additional measures
The device should not be used at the following locations unless additional measures are
taken:
● In locations with a high degree of ionizing radiation
● In locations with severe operating conditions, for example, due to:
● In systems that require special monitoring - for example:
Mechanical ambient conditions
The mechanical ambient conditions for the device are specified in the table below in terms of
sinusoidal vibration.
Frequency range f in Hz
5 Hz ≤ f ≤ 8.4 Hz
8.4 Hz ≤ f ≤ 150 Hz
Reducing vibrations
If the device is subjected to greater shocks or vibrations, you must take appropriate
measures to reduce acceleration or amplitudes.
We recommend mounting the device on damping materials, such as rubber-metal vibration
dampers.
Industrial Flat Panel IFP1500, IFP1900, IFP2200
Operating Instructions, 09/2012, A5E31298376-AA
– Corrosive vapors, gases, oils or chemicals
– Electrical or magnetic fields of high intensity
– Elevators
– Systems in especially hazardous rooms
Constant
Amplitude 0.0375 mm
Constant acceleration 0.5 g
Technical information
8.5 Technical specifications
Occasional
Amplitude 3.5 mm
Constant acceleration 1 g