Hexformat [Intel | Motorola]; Baud [Option] - Fujitsu F2MC-16L Series User Manual

Hide thumbs Also See for F2MC-16L Series:
Table of Contents

Advertisement

UPDATE controls the highlighting of the changed CPU register (see commands REGISTER,
EMULATION). If ALWAYS is selected the colouring is cleared after every display request. If
CHANGE is selected it keeps on colouring the last changes until the next modifying has been
done. Without parameter the current mode can be displayed.
Power on default is ALWAYS.
>update change↵
... Selects Change mode.
3.3.5.

HEXFORMAT [INTEL | MOTOROLA]

Change record format of SAVE command
This command is used to change the format of a HEX record dump via SAVE command (see
command SAVE). Without parameter the current mode can be displayed, otherwise the
requested format is set.
Power on default is INTEL.
>hexformat moto↵
... Selects Motorola format
BAUD [ O
3.3.6.
Set transmission rate of the external UART port
This command sets the transmission rate of the external UART port. Without parameter the
current mode can be displayed.
Options:
300,
>baud 38↵
... Sets 38400 Baud for the external port.
If the rate has been changed, the terminal baud rate must be changed, too. If they can not
immediately synchronise each other, the Monitor Reset button should be pressed.
NOTE: Another way to change the baud rate is the Auto-Connect function: The Escape key
(ASCII 27) of the terminal connected to the external port of the Evaluation Board
should be kept pressed to automatically repeat sending. Then the Monitor Reset must
be pressed (do not release the Escape key). After this, the monitor checks the terminal
baud rate and sets this rate as its own.
NOTE: The Auto-Connect function might be used for setting the user's favoured baud rate
that is stored as default of the terminal program. It might also be used to re-
synchronise the Evaluation Board, if an unexpected error occurred during download
and if the previous baud rate could not be reset.
NOTE: The power on default is 9600 Baud. If the value was changed by command or Auto-
Connect the monitor keeps this value also after a Monitor Reset. However, the next
power on reset will reset the rate to 9600 Baud.
The baud rate functions are NOT available for the internal UART port.
- 20 -
FUJITSU MB90675-Evaluation Board - User Manual
]
PTION
1200,
2400,
4800,
7200,
9600, 19200, 38400
© FUJITSU Mikroelektronik GmbH 1996