AREA C
3.2.11 STOP GATE MOTOR M3 & SENSOR Q7
[D]
Removal
1.
Remove Stop gate carriage (
2.
Remove nut [A] (
3.
Remove Crank arm [B].
4.
Remove screws [C] holding the motor (
5.
Loosen set screw [D] ( x1).
Replacement
1.
Mount the Crank pulley [E] without tightening the set screw [D] ( x1).
2.
Mount motor with screws [C] (
3.
Mount Crank arm [B].
4.
Tightening nut [A] (
NOTE: Make sure play for Crank arm [B] is maintained.
5.
Position the Crank pulley [E] so it is aligned with Crank arm [B].
6.
Tighten set screw [D] ( x1) on the flat of the shaft..
7.
Reinstall Stop gate carriage (
[E]
3.2.10).
x1).