ITEM:
Object manuals
S5U1C17001H2 User Manual
(Error)
Added.
(Correct)
(6) Check the current firmware version, and enter the following commands if updating is required.
When S1C17 processor is selected
(gdb) c17 fwe 0
(gdb) c17 fwe 1
(gdb) c17 firmupdate path¥filename.saf
When S1C33 processor is selected
(gdb) c33 firmupdate path¥filename.saf
path: Path for location of new firmware
filename.saf: File name for new firmware
The process is complete when the following is displayed after the commands have been entered.
When S1C17 processor is selected
(gdb) c17 fwe 0
Erase flash data ...done
(gdb) c17 fwe 1
Erase flash erase/write program ...done
(gdb) c17 firmupdate path¥filename.saf
Erase flash data ...done
Load flash data ....done
ICD firmware update ...done
Please quit gdb, and power off ICD when LED2/LED3/LED4 is green.
(LED is green in the case of SVT17701).
When S1C33 processor is selected
(gdb) c33 firmupdate path¥filename.saf
Erase flash data ...done
Load flash data ....done
ICD firmware update ...done
Please quit gdb, and power off ICD when OK LED is on.
This procedure may take about 15 minutes.
While firmware updating is in progress, do not reset the S5U1C17001H or turn off the power.
Otherwise it may not be possible to restart the S5U1C17001H.
S1C17 Manual errata