Drive-Cliq Interfaces X100 To X103 - Siemens SIMATIC S7-1500 Manual

Drive controller
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Note
Open input of digital inputs
An open input is interpreted as "low".
So that the digital inputs will function, connect terminal M1 or M2. The alternatives are as
follows:
• Connect the coupled reference ground of the digital inputs to M1 or M2.
• Connect a jumper to terminal M and terminal M1 (or between M and M2). This removes
the electrical isolation for these digital inputs.
The interfaces of the onboard I/O are described in section Digital inputs and outputs of X122,
X132 and X142 (Page 50).
3.6.3

DRIVE-CLiQ interfaces X100 to X103

DRIVE-CLiQ wiring of an axis group
The figure below shows a possible DRIVE-CLiQ wiring of an axis group.
Figure 3-4
SIMATIC Drive Controller
Equipment Manual, 11/2019, A5E46600370-AA
Example of a DRIVE-CLiQ wiring of an axis group
Connecting
3.6 Wiring and block diagrams
59

Advertisement

Table of Contents
loading

Table of Contents