2.6.2
View of SIMATIC Drive Controller without front covers
The figure below shows the operator controls and interfaces on the front of the SIMATIC
Drive Controller.
①
②
③
④
⑤
⑥
⑦
⑧
⑨
⑩
⑪
⑫
⑬
⑭
⑮
Figure 2-5
SIMATIC Drive Controller
Equipment Manual, 11/2019, A5E46600370-AA
X122, X132: 12 DI + 8 DI/DQ (assigned to SINAMICS Integrated)
X124: Connection for the 24 V DC supply voltage
X126: PROFIBUS DP interface
ACT LED: Display for access to SIMATIC memory card
FUNCT button for diagnostic purposes, see section FUNCT button (Page 42)
Protective conductor connection M5, Torx T25, tightening torque 3 Nm (26.6 lbf in)
X142: 8 DI/DQ (assigned to CPU)
PROFINET IO IRT (X150), with 3 ports: P1R, P2R, P3
PROFINET IO RT (X160), with 1 port (P1)
Basic PROFINET services (X130), with 1 port (P1), 1000 Mbps
LED displays
7-segment display, for diagnostic purposes
X50: Slot for SIMATIC memory card
Mode selector, see section Mode selector (Page 41)
X125, X135: 2 × USB 3.0 interface (no function assigned at present)
SIMATIC Drive Controller display and operator controls as well as interfaces
2.6 Operator controls, displays and connection elements
Product overview
33