Siemens SIMATIC S7-1500 Manual page 76

Drive controller
Hide thumbs Also See for SIMATIC S7-1500:
Table of Contents

Advertisement

Article number
Digital outputs
Type of digital output
integrated channels (DO)
Current-sinking
Current-sourcing
Digital outputs, parameterizable
Short-circuit protection
Response threshold, typ.
Limitation of inductive shutdown voltage to
Controlling a digital input
minimum pulse duration
Digital output functions, parameterizable
Freely usable digital output
Digital output with time stamp
PWM output
Cycle duration, parameterizable
ON period, min.
ON period, max.
Resolution of the duty cycle
Digital output with oversampling
Switching capacity of the outputs
with resistive load, max.
on lamp load, max.
Load resistance range
lower limit
Output voltage
Type of output voltage
Rated value (DC)
for signal "0", max.
for signal "1", min.
Output current
for signal "1" rated value
for signal "1" permissible range, min.
for signal "1" permissible range, max.
SIMATIC Drive Controller
Equipment Manual, 11/2019, A5E46600370-AA
6ES7615-4DF10-0AB0
Transistor
16; max. depending on parameterization
Yes; With High Speed output
Yes; Optionally as a P-switch or high-speed push-pull switch (high-
speed output)
Yes; 8 DI/DQ (X122/X132, SINAMICS Integrated) + 8 DI/DQ (X142,
PLC)
Yes; electronic/thermal
X122/X132: 1.4 A / X142: 0.9 A (high-speed output: 0.7 A)
X122/X132: max. -60 V / X142: max. -64.5 V
Yes
2 µs; For high-speed output, single pulse
Yes; Max. 8 (X122/X132) + max. 8 (X142)
Yes; Max. 8 (X142); e.g. for output cams
Yes; Max. 8 (X142)
Yes; Base frequency 1 / 2 / 4 / 8 / 16 kHz; specification of interpulse
period ratio over 32-bit pattern
0 %
100 %
3.125 %
Yes; Max. 8 (X142)
0.5 A; 0.4 A for high-speed output
5 W
48 Ω; with 24 V DC supply
DC
24 V
28.8 V
20.4 V
0.5 A; 0.4 A for high-speed output
2 mA
0.6 A; 0.48 A for high-speed output
Technical specifications
6ES7615-7DF10-0AB0