Siemens SITRANS LG240 Operating Instructions Manual page 53

Guided wave radar
Hide thumbs Also See for SITRANS LG240:
Table of Contents

Advertisement

Failure
Code
Cause
Text mes-
sage
F013
Sensor does not detect an
echo during operation
no measured
value avail-
Process component or probe
able
contaminated or defective
F017
Adjustment not within speci-
fication
Adjustment
span too small
F025
Index markers are not con-
tinuously rising, for example
Error in the
illogical value pairs
linearization
table
F036
Failed or interrupted software
update
No operable
software
F040
Hardware defect
Error in the
electronics
F041
Probe mechanically defective
Probe loss
F080
General software error
General soft-
ware error
F105
The instrument is still in the
start phase, the measured val-
Measured
ue could not yet be determined
value is deter-
mined
F113
EMC interference
Communica-
Transmission error during ex-
tion error
ternal communication with
4-wire power supply unit
PBD-51041037
Out of specification: The measured value is unreliable because an
instrument specification was exceeded (e.g. electronics temperature).
This status message is inactive by default.
Maintenance: Due to external influences, the instrument function
is limited. The measurement is affected, but the measured value is
still valid. Plan in maintenance for the instrument because a failure is
expected in the near future (e.g. due to buildup).
This status message is inactive by default.
Rectification
Check for correct mounting
and/or parameter settings
Clean or exchange process
component or probe
Change adjustment according
to the limit values (differ-
ence between min. and max.
≥ 10 mm)
Check values of the lineariza-
tion table
Delete/create a new lineariza-
tion table
Repeat software update
Check electronics version
Exchanging the electronics
Send instrument for repair
Exchanging the electronics
Send instrument for repair
Check probe and exchange, if
necessary
Disconnect operating voltage
briefly
Wait for the end of the switch-
on phase
Duration depending on the ver-
sion and parameter adjustment
max. 5 min.
Remove EMC influences
Exchange 4-wire power supply
unit or electronics
SITRANS LG240 - Operating Instructions
DevSpec State in CMD 48
Bit 0 of Byte 0 ... 5
Bit 1 of Byte 0 ... 5
Bit 2 of Byte 0 ... 5
Bit 3 of Byte 0 ... 5
Bit 4 of Byte 0 ... 5
Bit 13 of Byte 0 ... 5
Bit 5 of Byte 0 ... 5
Bit 6 of Byte 0 ... 5
Bit 12 of Byte 0 ... 5
53

Advertisement