Appendix 2
This section shows the system configuration in the following cases.
• The RJ71GN11-T2 is protocol version 1.0
• The CC-Link IE TSN module supports protocol version 1.0 only
• Set "Connection Device Information" under "Basic Settings" of the engineering tool to "Mixture of CC-Link IE TSN Class B/
A or CC-Link IE TSN Class A Only".
When "Connection Device Information" under "Basic Settings" of the master station is set to "Mixture of CC-Link IE TSN Class
B/A or CC-Link IE TSN Class A Only", up to 121 stations (1 master station and 120 device stations) can be connected.
No.0
No.1
Class B (1Gbps)
Class B (1Gbps)
General-
purpose
hub
No.0: Master station
No.1, No.2: Local station
No.3 to No.12: Remote station
(1), (2), and (3): Ethernet device
Class A: CC-Link IE TSN Class A device
Class B: CC-Link IE TSN Class B device
Appendix 2 System Configuration with CC-Link IE TSN Class B/A Devices (Protocol Version 1.0 Only) (RJ71GN11-T2)
System Configuration with CC-Link IE
TSN Class B/A Devices (Protocol Version
1.0 Only) (RJ71GN11-T2)
No.2
Class B (1Gbps)
TSN HUB
No.8
No.9
Class A
Class A
(1Gbps)
(1Gbps)
No.11
No.12
Class A
Class A
(100Mbps)
(100Mbps)
No.3
No.4
Class A
Class A
(100Mbps)
(100Mbps)
No.6
No.7
Class B (1Gbps)
Class B (1Gbps)
(3)
(1Gbps)
No.5
Class A
(100Mbps)
(1)
(1Gbps)
TSN HUB
(2)
(100Mbps)
No.10
Class A (1Gbps)
APPX
109
A

Hide quick links:

Advertisement

Table of Contents
loading

This manual is also suitable for:

Rj71gn11-t2Rj71gn11-sx

Table of Contents