Code PNU Size
H223
73
4
H024
74
4
0.001 - 9999.000kgm2
H224
75
4
0.001 - 9999.000kgm2
H030
76
4
H230
77
4
H031
78
4
H231
79
4
H032
80
4
H232
81
4
H033
82
4
H233
83
4
H034
84
4
0.001 - 9999.000kgm2
H234
85
4
0.001 - 9999.000kgm2
A043
86
2
A243
87
2
A343
88
2
A052
89
2
A055
90
2
A058
91
2
A064
92
2
A066
93
2
A068
94
2
A070
95
2
A073
96
2
A074
97
2
A075
98
2
A086
99
2
b003
101
2
b012
102
2
b212
103
2
b312
104
2
b015
105
2
b016
106
2
b017
107
2
b018
108
2
b019
109
2
b020
110
2
b100
111
2
"Free-setting, V/f frequency 2" Hz
b101
112
2
b102
113
2
"Free-setting, V/f frequency 3" Hz
b103
114
2
b104
115
2
"Free-setting, V/f frequency 4" Hz
b105
116
2
b106
117
2
"Free-setting, V/f frequency 5" Hz
Range
Magn.
0 - 655.30A
0 - 65.530OHM
*1000
0 - 65.530OHM
*1000
0 - 65.530OHM
*1000
0 - 65.530OHM
*1000
0 - 655.30mH
0 - 655.30mH
0 - 655.30A
0 - 655.30A
0 - 50.0%
0 - 50.0%
0 - 50.0%
0 - 60.00Hz
0 - 60.0s
0 - 60.0s
0 - 10.00Hz
0 - 10.00Hz
0 - 10.00Hz
0 - 60.0s
0 - 3600.0s
0 - 100.00
0.01 - 99.99%
0 - 100.0
0.3 - 100.0s
20.0 - 120.0%
20.0 - 120.0%
20.0 - 120.0%
0 - 400Hz
0 - 1000.0A
0 - 400Hz
0 - 1000.0A
0 - 400Hz
0 - 1000.0A
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 –
0.0 - 800.0V
0 –
Contents
*100
2nd No load current Io of motor
*100
1st Inertia J of motor
*100
2nd Inertia J of motor
1st Primary resistor R1 of motor (Auto)
2nd Primary resistor R1 of motor (Auto)
1st Secondary resistor R2 of motor (Auto)
2nd Secondary resistor R2 of motor (Auto)
*100
1st Inductance L of motor (Auto)
*100
2nd Inductance L of motor (Auto)
*100
1st No load current Io of motor (Auto)
*100
2nd No load current Io of motor (Auto)
*100
1st Inertia J of motor (Auto)
*100
2nd Inertia J of motor (Auto)
*10
1st Break point
of manual torque boost
*10
2nd Break point of manual torque boost
*10
3rd Break point of manual torque boost
*100
Frequency of DC braking start
*10
Time of DC braking working
Time of DC braking working for beginning of
*10
inverter running
*100
Width of jumping frequency 1
*100
Width of jumping frequency 2
*100
Width of jumping frequency 3
*10
Time of stopping to accelerate
*10
Integrate (I) gain of PID control
*100
Differential (D) gain of PID control
*100
Scale of PID control
*10
Response time of Energy saving function
*10
Waiting time of retry
*10
Level of 1st Electronic thermal protection
*10
Level of 2nd Electronic thermal protection
*10
Level of 3rd Electronic thermal protection
*1
Free electronic thermal frequency 1
*10
Free electronic thermal current 1
*1
Free electronic thermal frequency 2
*10
Free electronic thermal current 2
*1
Free electronic thermal frequency 3
*10
Free electronic thermal current 3
*1
Free V/F control frequency 1
*10
Free V/F control voltage 1
*1
Free V/F control frequency 2
*10
Free V/F control voltage 2
*1
Free V/F control frequency 3
*10
Free V/F control voltage 3
*1
Free V/F control frequency 4
24
Read/
L300P
Write
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
R/W
R/W
No
R/W
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/W
R/W
R/WOS
R/W
R/WOS
R/WOS
R/WOS
No
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS