Download Print this page

Hitachi SJ-PB2 Instruction Manual page 33

Profibus-dp communication board for sj700/sj300/l300p series inverter

Advertisement

Code PNU Size
C017 286
1
C018 287
1
C019 288
1
C101 289
1
C102 290
1
C103 291
1
C021 292
1
C022 293
1
C023 294
1
C024 295
1
C025 296
1
C026 297
1
C027 298
1
C028 299
1
C086 300
1
C031 301
1
C032 302
1
C033 303
1
C034 304
1
C035 305
1
C036 306
1
C040 307
1
C055 308
1
0 – 180% (75~132KW)
C056 309
1
0 – 180% (75~132KW)
C057 310
1
0 – 180% (75~132KW)
C058 311
1
0 – 180% (75~132KW)
C062 313
1
C070 314
1
C071 315
1
C072 316
1
C073 317
1
C074 318
1
C075 319
1
Range
00,01
00,01
00,01
00,01
00 - 02
00,01
00 - 13,19 - 26
00 - 07
00 - 07
0 - 10.0V
00,01
00,01
00,01
00,01
00,01
00,01
00,01
0 - 200% (~55KW)
0 - 200% (~55KW)
0 - 200% (~55KW)
0 - 200% (~55KW)
00 - 02
02 - 05
02 - 06
1 - 32
7,8bits
00 - 02
1,2bits
APPENDIX PARAMETER OBJECT LISTS
Magn.
Contents
Selection of a(NO) or b(NC) contact
code
in Intelligent input 7
Selection of a(NO) or b(NC) contact
code
in Intelligent input 8
Selection of a(NO) or b(NC) contact in
code
FW input
code
Selection of UP/DOWN function
code
Selection of RESET function
Selection of frequency matching function
code
at RESET
code
Selection of function in Intelligent output 11
code
Selection of function in Intelligent output 12
code
Selection of function in Intelligent output 13
code
Selection of function in Intelligent output 14
code
Selection of function in Intelligent output 15
code
Selection of function in Alarm relay output
code
Selection of FM function
code
Selection of AM function
*10
Adjustment of offset of AM
Selection of a(NO) or b(NC) contact
code
in Intelligent output 11
Selection of a(NO) or b(NC) contact
code
in Intelligent output 12
Selection of a(NO) or b(NC) contact
code
in Intelligent output 13
Selection of a(NO) or b(NC) contact
code
in Intelligent output 14
Selection of a(NO) or b(NC) contact
code
in Intelligent output 15
Selection of a(NO) or b(NC) contact
code
in Alarm relay output
Selection of output mode of overload
code
warning signal
Level of over torque in forward and
*1
drive (1st quadrant)
Level of over torque in reverse and
*1
regenerative (2nd quadrant)
Level of over torque in reverse and
*1
drive (3rd quadrant)
Level of over torque in forward and
*1
regenerative (4th quadrant)
code
Selection of Alarm code
code
Selection of Data command
Selection of communication speed for
code
*1
Selection of Inverter address for RS 485
*1
Selection of bit length of data for RS485
code
Selection of parity (odd or even) for RS485
*1
Selection of stop bit for RS485
29
RS485
Read/
L300P
Write
No
R/WOS
No
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
00 - 13
R/WOS
00 - 13
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
00 - 13
R/WOS
R/WOS
R/WOS
R/W
R/WOS
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
R/WOS
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
No
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS
R/WOS

Advertisement

loading

This manual is also suitable for:

Sj-pbt2